Physics in medicine and biology
Lattice peak optimization: a mixed-integer framework for geometry-adaptive lattice radiotherapy
Objective.Lattice radiotherapy (LATTICE) delivers spatially distributed high-dose peaks within the tumor volume while maintaining lower doses in surrounding valley regions. Determining feasible peak locations is typically performed using heuristic or manual approaches, which may limit the number and spatial distribution of deliverable peaks. This work introduces a lattice peak optimization (LPO) framework that jointly optimizes peak placement and dose distribution to identify the maximum number of geometrically feasible peaks within the target.Approach.Proton LATTICE planning is formulated as a mixed-integer optimization problem that selects an optimal subset of peaks from a large set of candidate locations within the target. Binary variables represent peak selection and continuous variables model spot weights. The formulation enforces geometric feasibility between peaks while optimizing dosimetric objectives to improve peak-to-valley dose ratio (PVDR) and reduce organs-at-risk (OAR) dose. The resulting nonconvex problem is solved using iterative convex relaxation within an alternating direction method of multipliers framework.Main results.LPO was evaluated on three clinical cases with 150-400 candidate peak locations, from which 4-13 peaks were selected. Compared with 50-90 randomly generated LATTICE configurations per case, LPO consistently achieved higher PVDR and improved OAR sparing. In an abdominal case, the composite objective value was 2.93 (worst random), 2.40 (median random), 1.90 (best random), and 1.95 (LPO), with similar trends observed across all cases.Significance.A geometry-adaptive, mixed-integer optimization framework for lattice peak placement is presented, demonstrating improved PVDR and OAR sparing relative to manual and random LATTICE approaches. The present study evaluates performance of the proposed framework in the context of proton LATTICE planning; however, the framework is mathematically modality-agnostic and could in principle be applied to other radiation modalities.
27 May 2026
Read appraisal →Physics in medicine and biology
FLIP-HEDOS: a patient-specific blood dose quantification model during radiotherapy treatments
Objective.To introduce FLIP-HEDOS, a blood dose modeling framework that combines patient-specific and generic circulatory data to enable individualized blood dose estimation during radiotherapy (RT) treatments and to overcome limitations of non-personalized approaches.Approach.Patient-specific images of vasculature were obtained from patients with thorax-abdomen or head-neck tumors treated with proton or photon RT. Large vessels from the tumor location were segmented, and their blood flow velocities were extracted from phase-contrast MRI. Movement of blood particles (BPs) was simulated using a Lagrangian approach along patient-specific flowlines in these vessels, forming the FLIP method. This circulation was incorporated into a standardized model (HEDOS) to form a closed-loop whole-body model that computes the spatiotemporal BP distribution and associated blood dose accumulation, accounting for dose delivery dynamics, dose rate and beam-on/beam-off times. Cardiac output (CO) was individualized to match each patient blood flow characteristics. FLIP-HEDOS retains the modular HEDOS architecture, extending its large vessel compartments with the FLIP approach patient-specific vessels represented as new compartments. Remaining compartments were adapted to preserve the standardized connectivity of the circulatory network.Main Results.The study quantified mean blood dose values and tracked the number of times BPs entered patient-specific compartments during dose delivery. Simulations were performed across a range of inter-beam intervals, and the three models FLIP (patient-specific vessels), HEDOS (generic whole-body), and FLIP-HEDOS (integrated model) were compared with respect to their resulting blood dose values. The comparison shows that when patient-specific information is incorporated in blood dose assessment, BPs experience higher radiation doses.Significance.FLIP-HEDOS proves that standardized vascular data can be effectively combined with patient-specific parameters to achieve physiologically realistic modeling of circulating blood. By enabling individualized CO and blood flow dynamics, the framework adapts to the anatomical and hemodynamic characteristics of each patient.
3 May 2026
Read appraisal →Biomedical physics & engineering express
Kali MC: an open-source toolkit for intraoperative electron radiation therapy treatment planning
Intraoperative electron radiation therapy (IOERT) is commonly delivered without intraoperative imaging, limiting patient-specific planning and requiring fast, reliable treatment calculations in the operating room. As a result, monitor unit (MU) calculations are often performed using spreadsheets and static look-up tables derived from measurements in water. We present Kali MC, an open source, Python-based software developed to streamline IOERT absorbed dose visualization, MU calculation and report generation for treatments delivered with the Liac HWL mobile accelerator. The software provides a graphical interface to visualize precomputed Monte Carlo absorbed dose distributions in water and performs MU calculations using experimentally determined output factors. Optional atmospheric pressure correction and predefined rescaling factors are supported to improve consistency of dose delivery and target coverage with the prescription isodose. Kali MC also generates customizable PDF treatment reports and exports DICOM RT Plan objects to facilitate integration with record-and-verify systems. By integrating validated dosimetric data, correction methods, and 3D dose visualization into a transparent platform, Kali MC supports efficient intraoperative decision-making; however, its use should be locally commissioned and evaluated according to institution-specific procedures and equipment characteristics.
28 Apr 2026
Read appraisal →Physics in medicine and biology
End-to-end testing of an online adaptive radiotherapy workflow for liver tumors using a dynamic Thoraco-abdominal anthropomorphic phantom.
Objective.Adaptive radiotherapy (ART) requires robust end-to-end (E2E) testing tools capable of reproducing organ deformation, physiological motion, and multimodal imaging properties. TheToraco-abdominalAnthropomorphic Phantom withMotion forAdaptiveRadiotherapy (TAM-ARa) is a dynamic anthropomorphic phantom developed to support the design, validation, and quality assurance of online ART workflows.Approach.The phantom was constructed with anatomically realistic bone, lung, and abdominal organ models fabricated from tissue equivalent materials. Modular components allowed simulation of interfractional and intrafractional anatomical variations, including ventilator driven respiratory motion, abdominal deformation, and variable gastric filling. CT, CBCT, and 3T MRI scans were acquired to assess imaging performance. Two E2E tests of an online adaptive intensity-modulated radiotherapy (IMRT) workflow for liver tumors were performed on a Varian Ethos (ETHOS, Varian, USA) system. Multiple deformation scenarios were investigated, including a static reference configuration, two abdominal and one thoracic deformation for ionization chamber (IC) dosimetry, and a static plus abdominal deformation scenarios for radiochromic film dosimetry.Main results.The TAM-ARa phantom demonstrated realistic radiological characteristics, with CT Hounsfield units and MRI relaxation times closely matching reportedin vivovalues. The modular architecture allowed reproducible and controlled abdominal deformations, while setup and dosimeter placement were completed within minutes. In E2E tests for adaptive IMRT of liver tumors, excellent agreement was achieved between measured and planned dose distributions after the treatment plan was adapted. IC E2E measurements showed that online adaptation consistently restored accurate dose delivery under deformation, reducing deviations to below 3%. Independent film measurements confirmed sub-millimeter geometric accuracy and full planning target volume coverage after adaptation, demonstrating effective compensation of deformation-induced errors.Significance.The TAM-ARa phantom provides a versatile and reproducible platform for multimodal E2E testing and validation of online ART workflows. Employing its realistic anatomical design, modular structure, and motion capabilities, TAM-ARa was successfully applied for E2E tests to validate a workflow for adaptive IMRT of liver tumors.
8 Apr 2026
Read appraisal →