Few shots transfer learning for universal SPECT denoising across diverse acquisition protocols
Clinical Snapshot
PICO Framework
| P — Population | 103 patients undergoing SPECT bone scans |
| I — Intervention | Transfer learning-based U-Net reconstruction framework for accelerated SPECT imaging |
| C — Comparator | Single model and base model approaches, standard full-scan SPECT protocols |
| O — Outcomes | Image quality metrics (PSNR, SSIM), clinical evaluation scores for image quality, radionuclide detail, artifacts, and diagnostic confidence |
Bottom Line
This technical validation study demonstrates that transfer learning can effectively address the challenge of SPECT image reconstruction from accelerated acquisition protocols. The approach shows promise for reducing scan times while maintaining diagnostic image quality across diverse acceleration scenarios. However, the study is limited by its single-centre design and modest sample size. While the technical results are encouraging, larger multi-centre validation studies are needed before clinical implementation. The method could potentially improve nuclear medicine workflow efficiency and patient experience, but requires careful validation of diagnostic accuracy in clinical decision-making scenarios. Implementation would need appropriate regulatory approval and quality assurance protocols.
Key Findings
P Value: Not reported
Effect Size: Highest PSNR of 48.02 and SSIM of 0.9918 in 30v6s protocol
Primary Outcome: Transfer model achieved superior PSNR and SSIM across all acceleration protocols
Nnt Or Sensitivity: Transfer model surpassed full-scan results in most clinical evaluation categories
Confidence Interval: Clinical scores: 4.667 ± 0.508 to 4.800 ± 0.250
Clinical Application
Requires implementation of deep learning infrastructure and training protocols in nuclear medicine departments Relevant to Australian nuclear medicine practice; could improve patient throughput and reduce waiting times while maintaining diagnostic quality under TGA medical device regulations Patients requiring SPECT bone scans where reduced acquisition time is clinically beneficial
Abstract
Objective.Accelerated single photon emission computed tomography (SPECT) imaging, achieved by reducing either the number of projection angles or the acquisition time per angle, enhances clinical workflow efficiency but introduces elevated noise. This study aims to develop and validate a universal DL-based reconstruction framework that effectively generalizes across diverse, clinically-realistic SPECT acceleration protocols by overcoming the data scarcity challenge.Approach.SPECT bone scans from 103 patients were acquired under a standard scan (60 views, 12 s/view, 60v12s) followed by a fast scan using one of five acceleration protocols (60v6s, 60v3s, 30v12s, 30v6s, 16v12s). AU-Net-based reconstruction framework was implemented using three strategies: (1) single model, trained on individual acceleration protocol), (2) base model, trained on aggregated datasets from five acceleration protocols, and (3) transfer model, fine-tuned from the base model for protocol-specific optimization. Pixel-level accuracy and structural similarity were assessed using peak signal-to-noise ratio (PSNR), structural similarity index (SSIM) metrics, and maximum pixel value of lesions. Clinical evaluation of image quality, radionuclide detail, artifacts, and diagnostic confidence was conducted using a 5-point system.Main results.Quantitative evaluation showed the transfer model achieved better PSNR and SSIM across all protocols (highest 48.02 PSNR and 0.9918 SSIM in 30v6 s protocol). Qualitative analysis confirmed enhanced structural fidelity. Clinical evaluations rated the transfer model highest across metrics, with scores of 4.667 ± 0.508 (image quality, 30v12 s), 4.800 ± 0.250 (radionuclide detail, 60v6 s), 1.150 ± 0.173 (artifact reduction, 60v6 s), and 4.800 ± 0.250 (diagnostic confidence, 60v6 s), surpassing full-scan results in most cases.Significance. The proposed transfer learning (TL) framework effectively addressed data scarcity and improved reconstruction performance across diverse SPECT acceleration scenarios. The adoption of a TL strategy mitigates data scarcity by utilizing shared features and fine-tuning for specific protocols. The framework demonstrates potential for integration into fast SPECT workflows, facilitating reliable use across diverse imaging scenarios.
References
- 1.Pan, B., Pan, J., Gan, K., Shen, Y., Chen, X., Zhong, L., Yang, H., Chen, J., Xie, L., Guo, W., Li, H., & Gong, N. J. (2026). Few shots transfer learning for universal SPECT denoising across diverse acquisition protocols. Physics in Medicine and Biology. https://doi.org/10.1088/1361-6560/ae5eb8
Related Research
European journal of radiology
A CT-based deep learning model to differentiate between benign and malignant adrenal lesions
3 Aug 2026
European respiratory review : an official journal of the European Respiratory Society
Prediction of PD-L1 expression in nonsmall cell lung cancer using artificial intelligence models based on radiomics: a systematic review and meta-analysis
10 July 2026
Radiation protection dosimetry
Impact of neutron sieve therapy for deep site in boron neutron capture therapy using Monte Carlo calculation
8 July 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service