Research Appraisalother

Dual-Signal Amplification Strategy for Synchronous Monitoring of Stress Hormones and Metabolic Indicators

Analytical chemistryZhao, Xiangchuan, Qin, Wenjing, Wang, Yanli et al.14 Apr 2026DOI

Clinical Snapshot

75CEBM
Evidence: Moderateother

PICO Framework

P — PopulationNot specified - laboratory-based sensor development study with ex vivo sweat samples
I — InterventionWearable electrochemical sensor with dual-signal amplification strategy using CuFe-PBA/CC substrate and MIP layer
C — ComparatorNot explicitly stated - appears to compare against baseline sensor performance without amplification
O — OutcomesDetection limits for cortisol (44.78 fM), glucose (0.064 μM), and uric acid (0.089 μM); sensor stability (88% signal retention after 100 cycles); real-time wireless detection capability

Bottom Line

This study presents a technically sophisticated wearable sensor capable of simultaneously detecting cortisol, glucose, and uric acid in sweat with impressive sensitivity. The dual-signal amplification strategy represents a significant technical advancement in biosensor technology. However, this remains a proof-of-concept study without clinical validation. While the detection limits are promising for non-invasive monitoring, the clinical correlation between sweat biomarker levels and systemic concentrations requires validation. The technology shows potential for stress assessment and metabolic monitoring but needs rigorous clinical testing, regulatory approval, and cost-effectiveness evaluation before clinical implementation. Healthcare professionals should view this as an emerging technology requiring further development rather than a ready-to-use clinical tool.

Evidence: Moderate

Key Findings

  • P Value: Not reported

  • Effect Size: Signal amplification to milliampere level with improved signal-to-noise ratio

  • Primary Outcome: Detection limits: cortisol 44.78 fM, glucose 0.064 μM, uric acid 0.089 μM

  • Nnt Or Sensitivity: 88% signal retention after 100 mechanical deformation cycles

  • Confidence Interval: Not reported

Clinical Application

Promising wearable technology but requires clinical trials before implementation Would require TGA approval as medical device; potential integration with digital health initiatives; relevance to chronic disease management programs under Medicare Potentially applicable to adults requiring continuous stress and metabolic monitoring, pending clinical validation

Abstract

The synchronous monitoring of stress hormones and metabolic indicators is crucial for long-term health management, yet it remains a significant challenge for wearable sensors, primarily due to the ultralow abundance of biomarkers in sweat and the vulnerability of weak electrochemical signals to interference. Herein, we report a wearable electrochemical sensor based on a dual-signal amplification strategy for the synchronous and highly sensitive detection of cortisol, glucose (Glu), and uric acid (UA). The CuFe-PBA/CC substrate provides a platform featuring high surface area, electrocatalytic activity, and dual signal amplification capabilities, which are the primary sources of high sensitivity. The MIP layer enhances the effective concentration of target substances near active sites through a local enrichment effect. Combined with the substrate's high catalytic activity, this amplifies the electrochemical signal specific to the target. It synergizes with an exogenous redox probe ([Fe(CN)6]3-/4-) to establish a dual-amplification pathway, which enhances the current output to the milliampere level and substantially improves the signal-to-noise ratio. To ensure the optimal performance of the sensor, the preparation parameters were optimized via the integration of machine learning. This integrated sensing system exhibits high selectivity, superior sensitivity (with detection limits of 44.78 fM for cortisol, 0.064 μM for Glu, and 0.089 μM for UA), and excellent stability (retaining 88% of the initial signal after 100 cycles of mechanical deformation). Furthermore, we fabricated the sensor into a watch-like form factor, integrated it with high-precision wearable electronic modules, and achieved real-time wireless detection of sweat cortisol, Glu, and UA in ex vivo sweat monitoring experiments. This work provides a novel solution for objective stress assessment and metabolic status monitoring, holding promise for advancing long-term health management applications.

References

  1. 1.Zhao, X., Qin, W., Wang, Y., Zhai, H., Gu, C., Bi, Y., Chen, M., Ming, Z., Li, S., Xu, Y., & Yin, S. (2026). Dual-Signal Amplification Strategy for Synchronous Monitoring of Stress Hormones and Metabolic Indicators. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c06744
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service