Research Appraisalother

Adherence Monitor for Measurement of Removable Cast Walker Wear-Time: Multiple Sensors and Predictive Analytics Improve Accuracy

Journal of diabetes science and technologyHavey, Robert M, Patwardhan, Avinash G, Stuck, Rodney M et al.1 May 2026DOI

Clinical Snapshot

55CEBM
Evidence: Weakother

PICO Framework

P — PopulationTen healthy volunteer subjects wearing removable cast walker boots for two weeks
I — InterventionElectronic wear-time monitor with multiple sensors (temperature, accelerometer, capacitive proximity sensors)
C — ComparatorSubject-reported wear diaries (self-reported don/doff times)
O — OutcomesAccuracy of wear-time measurement using correlation coefficients between sensor algorithms and diary records

Bottom Line

This technology validation study demonstrates that multi-sensor monitoring can accurately measure removable cast walker wear-time with 96% correlation to self-reported diaries. However, the study's major limitation is testing in healthy volunteers rather than diabetic patients with foot ulcers who would actually use this technology. While the technical performance appears promising, clinical validation is essential before implementation. The multi-sensor approach significantly outperformed individual sensors, suggesting sophisticated monitoring could improve adherence assessment in diabetic foot ulcer management. Australian clinicians should await clinical validation studies before considering adoption, though the technology could potentially enhance current diabetic foot care protocols if proven effective in real-world settings.

Evidence: Weak

Key Findings

  • P Value: P = 0.009 (differential temperature vs individual), P = 0.001 (accelerometer vs individual), P = 0.024 (foot proximity vs temperature), P = 0.005 (foot proximity vs acceleration)

  • Effect Size: Correlation coefficient of 0.96 for multi-sensor analysis

  • Primary Outcome: Correlation between multi-sensor algorithm and wear-time diaries

  • Nnt Or Sensitivity: Multi-sensor approach significantly more accurate than individual sensors

  • Confidence Interval: Not reported in abstract

Clinical Application

Technology appears feasible but requires validation in clinical population with cost-effectiveness assessment Could potentially support PBS-funded diabetic foot care programs if validated clinically, aligning with RACGP diabetes management guidelines emphasising adherence monitoring Limited applicability - study conducted in healthy volunteers rather than diabetic patients with foot ulcers

Abstract

BACKGROUND: Treatment of diabetes and its complications is a primary health care expense. Up to 25% of people with diabetes will develop diabetic foot ulcers (DFUs). Removable cast walker (RCW) boots commonly prescribed for DFU treatment, promote healing, and provide offloading and wound protection. Patient RCW removal for hygiene and wound care can lead to decreased adherence and treatment effectiveness. This study evaluated a new system for wear-time adherence measurement using multiple sensor types. METHODS: An electronic wear-time monitor was developed, which included internal and external temperature sensors, an accelerometer, and capacitive proximity foot and ankle sensors. Time-stamped and date-stamped data were saved once per minute for up to 22 days. Ten healthy volunteer subjects were recruited to wear an RCW for two weeks while keeping a diary of don/doff times. Sensor data were then compared with volunteers' wear diaries using confusion matrix predictive analytics. RESULTS: Algorithms were developed for data processing. Correlation coefficients between algorithms and diaries were calculated for individual and multiple sensor combinations. Differential temperature and accelerometer algorithms were significantly better at predicting subject wear-time than individual temperature sensor algorithms (P = .009, P = .001, respectively). Foot proximity had significantly better correlation with subject diaries than temperature (P = .024), and acceleration algorithms (P = .005). Multi-sensor analysis showed high correlation (.96) with wear-time from subject diaries. CONCLUSIONS: Removable cast walker wear-time can be accurately determined using an electronic data recorder and multiple sensors. Wear-time measurement accuracy can be improved using algorithms that operate on data from multiple sensors that use a variety of sensor technologies.

References

  1. 1.Havey, R. M., Patwardhan, A. G., Stuck, R. M., Keen, S. A., & Muriuki, M. G. (2024). Adherence Monitor for Measurement of Removable Cast Walker Wear-Time: Multiple Sensors and Predictive Analytics Improve Accuracy. Journal of Diabetes Science and Technology. https://doi.org/10.1177/19322968241304751
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service