A deep learning-based framework for patient-specific radiation dose prediction in beta-emitting radionuclide therapies
Clinical Snapshot
PICO Framework
| P — Population | Patients undergoing beta-emitting radionuclide therapy (Y-90, Ho-166, Lu-177) |
| I — Intervention | Deep learning model for dose prediction using CT-derived density maps and energy spectra |
| C — Comparator | Monte Carlo simulation, conventional DL model, voxel S-value (VSV), and OLINDA/EXM |
| O — Outcomes | Accuracy of voxel dose kernel prediction, organ dose estimation, computation time reduction |
Bottom Line
This methodological study presents a promising deep learning framework for patient-specific dose prediction in radionuclide therapy that eliminates the need for nuclear medicine imaging while maintaining high accuracy. The model demonstrated excellent correlation with Monte Carlo simulation (R² 0.99-0.91) and dramatically reduced computation time from hours to minutes. The zero-shot prediction capability for untrained radionuclides represents a significant advancement for clinical dosimetry. However, the study is limited by a small training cohort and lacks prospective clinical validation. While technically impressive, clinicians should await larger validation studies before clinical implementation. The approach could significantly streamline dosimetry workflows in Australian nuclear medicine departments if validated in broader patient populations.
Key Findings
P Value: Not reported
Effect Size: R² correlation of 0.99 for Ho-166 and 0.91 for Lu-177 in zero-shot prediction
Primary Outcome: Voxel dose kernel prediction accuracy compared to Monte Carlo simulation
Nnt Or Sensitivity: Computation time reduction from 4.6 hours to 2.6 minutes (98.9% reduction)
Confidence Interval: Not reported
Clinical Application
High feasibility using standard CT imaging without additional nuclear medicine scans Highly relevant to Australian nuclear medicine practice; could enhance PBS-funded radionuclide therapies by improving dosimetry accuracy and efficiency Patients receiving beta-emitting radionuclide therapy (Y-90, Ho-166, Lu-177) in nuclear medicine departments
Abstract
Objective.Conventional image-based models for radionuclide therapy dosimetry are typically radionuclide-specific and rely on nuclear medicine (NM) images for training. We developed a deep learning (DL) model that predicts doses for not only training radionuclides but also radionuclides not included in the training data without patient NM images.Approach.The DL model was trained to predict voxel dose kernels (VDKs) for beta-emitters using CT-derived density maps and energy spectra. The DL model-derived VDKs were convolved with time-integrated activity to generate patient-specific dose maps. Zero-shot prediction was tested on Ho-166 and Lu-177. The performance of DL model was validated at kernel, phantom, and patient levels. The proposed DL model, conventional DL model trained on Y-90 NM/CT images of 22 patients, voxelS-value (VSV), and organ-level dosimetry (OLINDA/EXM) were benchmarked against Monte Carlo simulation (MC).Main results.Training utilized a single CT image, circumventing large patient cohort requirements. The DL model-based VDKs showed strong correlation with MC-based VDKs (R2: 0.99 and 0.91 for test Ho-166 and Lu-177) and, at the phantom level, achieved overall lower errors than VSV in heterogeneous region. At the patient level, the proposed DL model predicted organ doses with the smallest differences from MC while reducing computation time from 4.6 h to 2.6 min. For the test Lu-177, the proposed model exhibited good agreement with MC (2.1 Gy, 11.6%), while the conventional model trained using Y-90 showed large discrepancies (129.4 Gy, 657.4%). For the mean tumor dose averaged across the patient cohort for test Ho-166, the proposed DL model yielded the most accurate results with a difference of only 1.1 Gy (2.9%), outperforming multiple VSV (3.8 Gy, 7.2%), single VSV (3.8 Gy, 7.3%), and OLINDA/EXM (1.4 Gy, 4.5%).Significance.The proposed DL model enables dose prediction for radionuclides not included in the training data without NM images.
References
- 1.Ha, S., Kang, H., Kang, D. S., Jang, J., Oh, J. S., & Sung, W. (2026). A deep learning-based framework for patient-specific radiation dose prediction in beta-emitting radionuclide therapies. Physics in Medicine and Biology. https://doi.org/10.1088/1361-6560/ae5375
Related Research
European journal of radiology
A CT-based deep learning model to differentiate between benign and malignant adrenal lesions
3 Aug 2026
European respiratory review : an official journal of the European Respiratory Society
Prediction of PD-L1 expression in nonsmall cell lung cancer using artificial intelligence models based on radiomics: a systematic review and meta-analysis
10 July 2026
Radiation protection dosimetry
Impact of neutron sieve therapy for deep site in boron neutron capture therapy using Monte Carlo calculation
8 July 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service