Research Appraisals
Evidence-based critical appraisals of the latest medical research, systematically evaluated using Oxford CEBM methodology.
Showing 12 appraisals
ACS applied materials & interfaces
Breathable and Washable E-Textile with Readily Integrated Piezoelectric Perfluoroalkoxy Fiber for Wide Temperature Range Human Machine Interfaces
Flexible wearable sensors are widely explored for human-machine interaction and health monitoring. Electronic textiles (E-textiles) offer a promising pathway toward comfortable wearable devices by integrating sensing fibers directly into fabric structures. Among them, compared with piezoresistive and capacitive fiber sensors, piezoelectric fiber sensors require no external power supply. Compared with triboelectric fiber sensors, which are highly sensitive to humidity and temperature, piezoelectric fiber sensors provide more stable and reliable electrical signals. However, conventional piezoelectric fiber sensors still face challenges in achieving long-term wearing comfort and reliability under harsh environments. Herein, we develop a breathable, washable, and wide-temperature-tolerant based on piezoelectric perfluoroalkoxy (PFA) fibers, which can be readily integrated into E-textiles. The textile is produced via a weft knitting process that integrates coaxially structured PFA fibers with wool yarns, combining stable piezoelectric performance with wearing comfort. The fibers exhibited a charge sensitivity of (2.6 ± 0.2) pC/N at 0.2 MPa. The resulting E-textile exhibits a charge sensitivity of up to (316.6 ± 45.9) pC/N and a voltage sensitivity of (744.9 ± 73.9) mV/N. The textile maintains stable operation over a wide temperature range from -78 °C to 150 °C. Its weft-knitted structure provides breathability, while the textile also offers washability, UV resistance, and mechanical durability exceeding 10,000 stretching or bending cycles. Furthermore, the textile can effectively monitor various human motions. A smart glove constructed from five-channel PFA fibers achieved recognition accuracies above 95% for five hand gestures, demonstrating the potential offer self-powered E-textile as a wearable sensor for human-machine interaction.
30 May 2026
Read appraisal →ACS applied materials & interfaces
Boosting Piezoelectricity and Mechanical Properties of Silk Fibroin Films via Polyethylene Glycol Phase Manipulation
Piezoelectric silk fibroin (SF) shows great potential in fabricating sustainable wearable electronics toward health monitoring and human-machine interfacing, yet the processing difficulty and brittleness restrict its practical applications severely. This study proposes a simple strategy to achieve the boosted piezoelectricity and mechanical properties in electrospun regenerated silk fibroin (RSF) nanofiber mats by adding polyethylene glycol (PEG) with different molecular weights to induce the formation of β-sheets via hydrogen bonding and the regulation of PEG phase morphology. Specifically, RSFs consisting of PEG of 2000 and 1000 Da exhibit a significant improvement in the tensile strength (from 6.1 to 9.92 MPa) and elongation at break (from 5.72% to 117.58%), respectively. Meanwhile, RSFs consisting of PEG with a molecular weight of 2000 and 400 Da show a direct piezoelectric force sensitivity of 0.2 mV/N·μm and 0.14 mV/N·μm respectively, superior to that of pure RSF (0.04 mV/N·μm). The piezoelectric force sensors fabricated with RSFs show potential applications in the detection of diverse human motions, including finger tapping for Morse code, grip strength, and knee flexion. Thus, this work unveils a facile strategy to fabricate RSF-based biodegradable piezoelectric force sensors with a trade-off in processability, mechanical ductility, and piezoelectricity.
28 May 2026
Read appraisal →Biomaterials science
Hydrogel-based wearable and implantable biosensors in health monitoring.
Hydrogel-based wearable and implantable biosensors have quickly established themselves as a paradigm-shifting platform for continuous health monitoring. They effectively reconcile the mechanical and chemical discrepancies between conventional rigid electronics and delicate biological tissues. This success is largely attributed to the hydrogel material's inherent advantages: high water content, a precisely tunable elastic modulus, and versatile functional chemistry. Collectively, these features provide structural, biological, and processing benefits that facilitate truly seamless bioelectronic integration. This Review systematically summarizes the latest advancements in hydrogel biosensors, placing emphasis on their distinctive material attributes. These include the synergistic ionic-electronic conduction, sensitive stimuli responsiveness, advanced antifouling surface chemistry, and exceptional tissue-mimicking compliance. We further delve into the fundamental physical and chemical sensing mechanisms, supported by representative applications spanning from the non-invasive, real-time analysis of sweat, tears, saliva, and interstitial fluids to the more complex domains of subcutaneous, cardiac, and neural implants. Finally, we candidly address the crucial hurdles that remain, such as long-term hydration stability, signal fidelity drift, and adverse immune responses. Concurrently, we highlight pioneering strategies to overcome these issues, including the adoption of zwitterionic designs for enhanced biocompatibility, nanocomposite reinforcement for mechanical robustness, and the utilization of transient biodegradability. By critically elucidating the intricate relationships governing hydrogel structure, chemistry, and bioelectronic function, this Review aims to chart the research trajectory toward the next generation of durable, self-healing, and fully biointegrated sensing systems.
11 May 2026
Read appraisal →Carbohydrate polymers
Multifunctional starch-based eutectogels with high mechanical properties, adhesion, self-healing, fatigue resistance and degradability for flexible wearable sensing
Flexible wearable sensors have developed rapidly due to the urgent demands for human motion monitoring. Eutectogel-based soft materials have exhibited great potential for wearable sensing applications. However, it is still a challenge to develop multifunctional eutectogels with excellent mechanical properties, adhesion, self-healing, fatigue resistance and degradability. In this work, a multifunctional starch-based eutectogel was developed by a one-pot and in-situ photo-polymerization method. The eutectogel had excellent stretchability (2710%), high strength (5.43 MPa), toughness (94.38 MJ/m3), Young's modulus (10.23 MPa), adhesion, fatigue resistance (1000 cycles), degradability and a certain degree of self-healing ability. These properties were closely correlated to the synergistic effect among the amylopectin, polyacrylic acid and choline chloride via hydrogen-bond and electrostatic interactions. The mechanical properties of eutectogel can be adjusted by changing the starch content. A wearable sensor based on the eutectogel was realized accurate and stable monitoring of human joint motions. This study addressed the limitations of the dehydration and single function of the traditional hydrogels, and provides a novel way for the development of the multifunctional bio-based gels for next-generation flexible wearable devices.
9 May 2026
Read appraisal →Advances in colloid and interface science
Electrospun nanofibrous membranes for self-powered wearable air filtration systems
With the growth of society and industrialization, air pollution has intensified, disturbing the ecological balance and presenting considerable risks to human health. The development of intelligent wearable protective systems is a major breakthrough in real-time health monitoring and prevention, greatly improving personal health management outcomes. An optimal smart air filtration system must demonstrate reliable filtration efficiency, minimal air resistance, and incorporate features for health monitoring and interaction with users. As a result, it is essential to create innovative materials for air filtration that can effectively trap particulate matter (PM). The adaptability, high surface area, interconnected porosity, and configurable morphology of electrospun nanofibers make them a highly promising platform for developing high-performance air filtration media. The conversion of ambient mechanical vibrations into electrical power by piezoelectric and triboelectric nanogenerators (PENGs and TENGs) has emerged as a practical strategy for effective energy harvesting. Integrating self-powered technologies with fibrous air filtration materials to efficiently eliminate fine particulate matter provides a new and sustainable approach to air purification. This review systematically summarizes recent advances in electrospun nanofibrous membranes for self-powered, intelligent, wearable air filtration systems. It begins with an analysis of the fundamental mechanisms of air filtration, the criteria for performance evaluation, and the principles of electrospinning technology. Subsequently, the practical application performance of these filtration systems is critically examined. Finally, the review outlines prospective research directions and discusses the remaining challenges confronting self-powered air filtration systems.
4 May 2026
Read appraisal →ACS sensors
Wearable Flexible Acoustic Alarm Device Based on MXene/Laser-Induced Graphene@Polyimide Thermoacoustic Film
Flexible acoustic devices have advantages of high flexibility and large sound output area, capable of adhering to the surface of the skin or clothing, which shows great potential in the field of wearable electronics. However, the design of acoustic material structures and their functional applications are still difficult. Here, we fabricated a porous laser-induced graphene (LIG) microarray layer on a polyimide (PI) film by laser direct writing. Subsequently, we uniformly coated the few-layer MXene nanosheets onto the LIG surface to obtain an MXene/LIG@PI film featuring low specific heat capacity per unit area, large interlayer spacing, excellent electrical conductivity, and high thermal conductivity. Meanwhile, the MXene/LIG@PI-based acoustic device composed of flexible copper electrodes exhibits excellent acoustic performance with a high sound pressure level of 77.6 dB and maintained a stable acoustic spectrum as the frequency increased from 20.0 Hz to 20.0 kHz. Finally, the portable acoustic alarm device composed of the piezoelectric module and the MXene/LIG@PI-based acoustic module was designed, which can be worn on various parts of the human body clothing, to provide audible alarm reminders in case of accidental falls or drops during outdoor activities. This study provides a novel approach for designing new flexible acoustic materials and devices.
26 Apr 2026
Read appraisal →Nanoscale
Bifunctional PVDF/MXene membranes with high piezoelectric sensitivity and near infrared photothermal antibacterial efficacy toward wearable human activity monitoring
In the realm of wearable health monitoring, establishing a reliable interface that ensures both high-fidelity sensing and long-term biological safety remains a critical challenge, particularly due to the risk of bacterial infection caused by sweat accumulation at the device-skin contact. Herein, we address this issue by developing a scenario-driven, bifunctional PVDF/MXene nanofibrous membrane that integrates robust piezoelectric performance with on-demand photothermal antibacterial capability. In this design, MXene nanosheets function simultaneously as nucleating agents to boost the electroactive β-phase content of PVDF from 80.3% to 93.3% and as efficient near-infrared (NIR) photothermal agents. The optimized membrane exhibits a superior piezoelectric sensitivity of 0.502 V/N, enabling the precise detection of diverse human activities ranging from subtle pulse waveforms to vigorous jumping motions, and motion-triggered Morse code communication. Crucially, addressing the hygiene concerns of reusable wearables, the membrane achieves rapid, non-contact sterilization during off-wear intervals. Under safe NIR irradiation (0.3 W cm-2), the surface temperature rises to ∼60 °C within 60 s, achieving an antibacterial efficacy of >99% against S. aureus and E. coli. Combined with excellent in vitro cytocompatibility, this work provides a "one-structure, dual-function" solution for constructing hygienic, high-performance electronic skins.
17 Apr 2026
Read appraisal →Biomacromolecules
A Phase-Separated Cellulose-Ionogel via Sunlight-Initiated Green Fabrication for Self-Powered Wearable Sensors
Ionogels, as soft ionic conductors, face synthesis challenges including toxicity, complexity, and high energy consumption. Herein, we present a green one-pot strategy that effectively dissolves cellulose and undergoes sunlight-induced photopolymerization to form ionogels without the need for cross-linkers or initiators. 1-Butyl-3-methylimidazolium chloride ([BMIM]Cl), as the solvent, enables the disruption of the extensive hydrogen-bond network of cellulose, resulting in rapid and complete dissolution. Subsequent one-step photopolymerization, which proceeds solely under sunlight, simultaneously drives in situ cross-linking and a controlled phase separation process, yielding high-performance ionogels. Importantly, the resulting cellulose ionogel exhibits superior fracture strength (2.75 MPa), high toughness (18.4 MJ m-3), and strong adhesion (6.6 MPa), ameliorating the traditional trade-off between mechanical strength and adhesion capabilities. This work develops an integrated ionogel platform as a soft TENG electrode for human motion monitoring, informing the design of sustainable self-powered electronics.
14 Apr 2026
Read appraisal →Biomacromolecules
Highly Flexible, Adhesive, Antimicrobial, and Self-Powered Hydrogel Strain Sensor for Human Motion Monitoring
Piezoelectric hydrogel sensors are a recent innovation that combines the flexibility of hydrogels with the self-powering of piezoelectric materials. Here, we present a self-powered hydrogel strain sensor by incorporating piezoelectric Na0.5Bi0.5TiO3 nanoparticles into a dual-network hydrogel composed of poly(vinyl alcohol), acrylamide, and 2-acrylamido-2-methyl-1-propanesulfonic acid. The hydrogel exhibits excellent mechanical properties, achieving a tensile strength of 1.28 MPa, an elongation at break of 1127%, and strong tissue adhesion (55.97 kPa on porcine skin). The sensor delivers a maximum output voltage of 237.4 mV, a sensitivity of 17.99 mV under small compressive strain, and a broad tensile strain detection range of 30 to 400%. It reliably monitors both subtle physiological activities (facial expression, swallowing, pulse) and large joint movements. Moreover, it exhibits notable antibacterial performance via ultrasound-driven piezocatalysis, reducing bacterial viability to below 1.5%. This tough, adhesive, and antibacterial piezoelectric hydrogel sensor holds significant promise for wearable electronics and human-machine interfaces.
14 Apr 2026
Read appraisal →ACS applied materials & interfaces
Physically Cross-Linked Biopolymer-Based Strong and Stretchable Organohydrogel with Self-Healing and Biocompatibility for Environmentally Tolerant Strain Sensors
The development of wearable strain sensors increasingly focuses on multifunctional materials that integrate mechanical robustness, self-repairing capacity, temperature-resilient conductivity, and biocompatibility. Herein, we developed a physically cross-linked biopolymer-based organohydrogel by incorporating gelatin (Gel) and β-cyclodextrin-grafted chitosan (CDCS), designated as Gel/CDCS, reinforced through hydrogen bonding, ionic interactions, and host-guest complexation. The optimized Gel/CDCS1 organohydrogel with 1% of CDCS exhibited outstanding stretchability, with a tensile strain at break of 410.9% and a tensile strength of 92.2 kPa, while maintaining 85% of its mechanical properties after self-healing at 40 °C. The introduction of kosmotropic salts (Na3Cit and NaCl) and a glycerol-water binary solvent system conferred remarkable environmental adaptability, allowing stable performance from -20 to 37 °C. Notably, it achieved a high ionic conductivity of 0.946 S m-1 at room temperature, alongside 0.606 S m-1 at -20 °C and 0.330 S m-1 at 37 °C, ensuring operation under extreme conditions. The strain sensor displayed high sensitivity with a gauge factor (GF) increasing from 1.06 to 1.34 over a broad strain range and maintained a stable electrical response over 600 consecutive stretching cycles. Additionally, it enabled reliable detection of diverse human motions, including facial expressions, joint bending, and breathing, demonstrating excellent conformability and signal stability during on-body monitoring. Additionally, Gel/CDCS1 exhibited excellent biodegradability, degrading by over 80% in soil within 4 days, and showed high biocompatibility with fibroblast viability of around 80%. These attributes establish Gel/CDCS1 as a promising eco-friendly candidate for next-generation flexible electronics, wearable strain sensors, and biomedical applications.
10 Apr 2026
Read appraisal →ACS applied materials & interfaces
Textile-Based Wearable Electrothermal Pad Using Woven AgNW/EG-PEDOT:PSS Heaters and PS/PEDOT:PSS Thermistor Yarns
Wearable thermal management devices are gaining increasing attention for healthcare, rehabilitation, and personal comfort applications. Here, we present a textile-based wearable electrothermal pad that integrates a woven heater with a yarn temperature sensor on a flexible, breathable fabric platform. The heater element was fabricated using cotton yarn coated with silver nanowires (AgNW) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) doped with ethylene glycol (EG-PEDOT:PSS), enabling uniform heat distribution, washability, and low-voltage operation. The AgNW/EG-PEDOT:PSS yarn heater rapidly reached 45 °C within 60 s at an applied voltage of 1.5 V and demonstrated good thermal stability and repeatability over 2,000 stretching-releasing cycles. The temperature sensor, based on polystyrene-coated PEDOT:PSS (PS/PEDOT:PSS) yarn, exhibited thermistor behavior with resistance decreasing as the temperature increases. It showed a negative temperature coefficient of resistance of 0.25%°C-1 and a response time of less than 130 s. The yarn temperature sensor also maintained resistance stability under bending and stretching-releasing conditions. To demonstrate a wearable electrotherapy platform, the PS/PEDOT:PSS yarn temperature sensor was integrated with a woven AgNW/EG-PEDOT:PSS heater to enable closed-loop feedback for thermal regulation. Programmable, on-demand thermotherapy and real-time thermal management could be wirelessly controlled via a smartphone. This custom-designed electrothermal pad offers a promising solution for wearable thermotherapy and smart clothing applications.
10 Apr 2026
Read appraisal →ACS applied materials & interfaces
NeuroTex: Functionalized Hybrid Polymer-Metal Textile for Soft, Robust, and Dry Auricular Neural Interfaces
Wearable bioelectronics would benefit from dry, easy-to-apply electrodes for sensing physiological signals. Bioelectronic interfaces must maintain high conductivity, low electrode-skin impedance, and reliable coupling between the electrode and skin under sweat, motion, and prolonged use. Metallic textiles offer good conductivity and stable connections but are hydrophobic, prone to cracking and oxidation, and dependent on conductive gels to achieve the low impedance required for low-amplitude electrophysiological signals. Here, we introduce NeuroTex, a commercially available silver nanowire textile that is PEDOT:PSS-functionalized to improve the electrode-skin-electronics interface. The PEDOT:PSS coating reduced the area-normalized resistance of the textile by almost 50%, suppressed silver oxidation in phosphate-buffered saline, and lowered the contact impedance by more than 85%. Mechanical evaluations under torsion, stretching, bending, and low-force fatigue confirmed the preserved fiber integrity and intact electronic connectivity. Furthermore, the soft and hydrophilic properties of the coating enhanced the conformal skin interfacing. Integrated into an in-ear monitoring platform, NeuroTex enabled multimodal biosignal recordings of in-ear electroencephalography (ieEEG), electro-oculography (ieEOG), electromyography (ieEMG), and electrocardiography (ieECG). Reliable acquisition of the technically demanding ieEEG signal was achieved, demonstrating alpha-modulation responses comparable to those of gel-based electrodes. ieEEG recordings recorded over several hours captured distinct sleep patterns to further confirm stable performance during natural sleep. These results establish NeuroTex as a gel-free, mechanically resilient, and electrochemically stable interface suitable for wearable physiological monitoring.
10 Apr 2026
Read appraisal →