Evidence-Based Medicine

Research Appraisals

Evidence-based critical appraisals of the latest medical research, systematically evaluated using Oxford CEBM methodology.

Showing 2 appraisals

otherEvidence: Weak
40CEBM

Journal of diabetes science and technology

Diabetes-Technology and Waste: The Future is Now.

The downside of the success story of diabetes technology is the amount of waste generated by manufacturing and using such medical products. Quantitative surveys performed in the United States and Germany document how many pounds of plastic waste, batteries, and electronic parts are piling up per patient with diabetes each year; however, the actual environmental burden of diabetes care has not been assessed yet. Given the highly probable further increase in usage of diabetes technology devices, what are the options to change the situation? Ideally, one would avoid generating waste by optimizing the design of the products (Eco-Design); however, this approach faces a number of complex regulatory and economic hurdles. The issue of waste management is becoming increasingly important as the use of wearable devices increases. Stewardship of the environment will require all stakeholders to address waste management.

4 May 2026

Read appraisal →
observationalEvidence: Moderate
85CEBM

The Journal of clinical investigation

Disrupted neurovascular-endocrine coupling in type 1 diabetes with impaired awareness of hypoglycemia

BACKGROUNDRecurrent hypoglycemia in type 1 diabetes (T1D) may culminate in impaired awareness of hypoglycemia (IAH). While neuroimaging studies identified affected brain regions, more complex perspectives integrating vascular dynamics with endocrine profile are needed.METHODSHere, 26 healthy adults, 30 T1D patients with normal hypoglycemia awareness (NAH), and 25 T1D patients with IAH underwent a hyperinsulinemic stepped clamp (euglycemia → hypoglycemia 50 mg/dL) combined with pseudo-continuous arterial spin-labeling MRI. Cerebral blood flow (CBF) and sympathetic vasomotor range (0.02-0.05 Hz) CBF oscillations were modeled against serially sampled plasma cortisol, epinephrine, norepinephrine, and glucagon.RESULTSIn healthy individuals treated as controls, hypoglycemia evoked robust thalamo-striatal and salience-interoceptive CBF increases (mean Cohen's d across significant clusters = 0.93) and suppression of vasomotor oscillations (d = 0.71). T1D retained CBF response but failed to attenuate oscillations (dT1D>controls = 0.43). IAH further blunted hypoglycemia-associated CBF increase, especially in thalamus, striatum, and insula (dNAH>IAH = 0.51). Hormone-CBF coupling differed quantitatively: cortisol/epinephrine-CBF correlations were positive in controls (r = 0.37/0.26), negative in NAH (-0.16/-0.40), and strongly positive in IAH (0.42/0.46).CONCLUSIONThus, our findings indicate that T1D disrupts dynamic, sympathetic modulation of CBF, whereas IAH additionally impairs perfusion reserve and shows maladaptive catecholamine-dependent CBF regulation, suggesting a qualitatively distinct neurovascular phenotype.TRIAL REGISTRATIONClinicalTrials.gov: NCT02747680 and NCT02866435.FUNDINGNIH (P41-EB-015894, P30-NS-076408, R01-DK-099137, R56-DK-099137, and DP1 AG093028); National Center for Advancing Translational Sciences of the NIH (KL2-TR-000113 and UL1-TR-000114); DP1 AG093028; Charles University, Czech Republic (Cooperatio Program, research area NEUR), Brain Dynamics (grant number CZ.02.01.01/00/22_008/0004643); General University Hospital in Prague (MH CZ-DRO-VFN64165).

16 Apr 2026

Read appraisal →