Research Appraisals
Evidence-based critical appraisals of the latest medical research, systematically evaluated using Oxford CEBM methodology.
Showing 2 appraisals
Biomedical physics & engineering express
Simulation-driven deep learning for the diagnosis of middle ear pathologies using wideband acoustic immittance
Wideband acoustic immittance (WAI) provides comprehensive frequency-dependent information for diagnosing middle ear pathologies. However, the scarcity of clinical data and complex response patterns significantly hinder automated diagnosis, particularly in data-limited scenarios. To address this issue, this study proposes a simulation-driven computer-aided diagnosis framework for WAI based on finite element (FE) modeling. Latin hypercube sampling was employed to systematically perturb key physiological parameters of the human ear FE models, generating a standardized virtual WAI dataset comprising 12 000 samples across the 0.2-6 kHz frequency range. The dataset includes four middle ear conditions: normal ear, ossicular chain discontinuity, ossicular chain fixation, and otitis media with effusion. Based on this dataset, a lightweight convolutional neural network tailored for multi-channel WAI inputs, termed WAIHybrid, was developed. It was benchmarked against traditional feature-based machine learning models and five representative deep learning architectures on simulated data and subsequently evaluated on an external clinical dataset comprising 206 ear-level WAI records. WAIHybrid achieved a macro-F1 of 96.30% and a balanced accuracy of 96.29% on an independent simulated test set. On the external clinical dataset, the corresponding values were 87.76% and 88.07%, respectively. Response-level comparisons, learned-representation analyses, and Integrated Gradients maps identified partial class-related correspondence between the simulated and clinical data, residual simulation-to-clinical discrepancy, and class-dependent channel-frequency attribution patterns. These findings support a simulation-driven proof of concept for automated WAI analysis in data-limited middle ear assessment. Further evaluation in larger, more balanced, and clinically heterogeneous cohorts is needed.
19 July 2026
Read appraisal →European journal of radiology
Deep learning-based segmentation and quantification of pulmonary masses on apparent diffusion coefficient maps: a multicentre reproducibility study
OBJECTIVES: To develop and validate a deep learning model for automatic segmentation of pulmonary masses on apparent diffusion coefficient (ADC) maps and to assess repeatability of automated ADC quantification. METHODS: We proposed ADCSegNet, a deep learning model tailored to pulmonary ADC maps, trained and tested on ADC maps from centre 1 (303 MRI examinations) and externally evaluated on datasets from centre 2 (70 examinations) and centre 3 (12 examinations) for generalisability. Segmentation accuracy was evaluated using the Dice similarity coefficient (DSC). Agreement between model-derived and manual ADC measurements (senior and junior radiologists) was examined using Bland-Altman analysis, the intraclass correlation coefficient [ICC(2,1)], and the reproducibility coefficient (RDC) following QIBA profiles. Repeat-scan stability was assessed on an independent prospective test-retest dataset (22 × 2 examinations) using Lin's concordance correlation coefficient (CCC). RESULTS: ADCSegNet achieved DSCs of 0.843 internally and 0.701 externally, outperforming nnU-Net and other contemporary backbones. Agreement was highest between the model and the senior radiologist; for mean ADC, the mean difference was 0.00 (95% limits of agreement, -0.13 to 0.13) × 10⁻3 mm2/s, exceeding model-junior and inter-radiologist agreement. ICC(2,1) exceeded 0.75 for most ADC metrics, and RDC confirmed high reproducibility for key metrics (mean ADC RDC%: 12.98% for model-senior vs. 22.87% for senior-junior radiologist). Test-retest analyses showed higher repeatability of ADCSegNet than radiologists for core metrics such as mean ADC (CCC 0.931 vs. 0.908). CONCLUSIONS: ADCSegNet enables accurate segmentation of pulmonary masses on ADC maps and provides reproducible automated ADC quantification, outperforming state-of-the-art backbone models while showing strong agreement with expert readers and stable performance on repeat scans.
4 July 2026
Read appraisal →