Three-dimensional stability during orthodontic retention: A comparative analysis of conventional, CAD/CAM-fabricated, and robotically bent fixed retainers versus removable appliances
Clinical Snapshot
PICO Framework
| P — Population | 113 patients (226 dental arches) who completed orthodontic treatment requiring retention, mean retention period 1.3 ± 0.6 years |
| I — Intervention | Combined fixed lingual plus removable retention using CAD/CAM Memotain, conventional multistranded stainless-steel (Twistflex), and robotically bent retainers |
| C — Comparator | Removable retention only |
| O — Outcomes | Three-dimensional tooth position changes, rotational and translational movements, Little's Irregularity Index, transverse arch widths, bonding failures, and stability rates |
Bottom Line
This retrospective cohort study of 113 patients demonstrates superior three-dimensional stability with combined fixed and removable retention compared to removable appliances alone (55% vs 33% stable arches). Fixed lingual retainers provided strong protective effects against moderate-to-severe instability (OR 0.07-0.23). While all fixed retainer designs outperformed removable-only retention, robotically bent and CAD/CAM fabricated retainers showed marginally lower dimensional variability. The 25% bonding failure rate emphasises the critical importance of regular monitoring. For Australian orthodontists, these findings support current evidence favouring fixed retention for high-risk patients, though the relatively short 1.3-year follow-up limits long-term conclusions. The study's objective 3D measurement methodology strengthens confidence in the findings, but the retrospective design and single-centre recruitment limit causal inference.
Key Findings
P Value: Not explicitly reported but confidence intervals exclude null
Effect Size: Combined fixed and removable retention: 55% stable arches vs removable-only: 33% stable arches
Primary Outcome: Three-dimensional tooth stability during orthodontic retention
Nnt Or Sensitivity: Number needed to treat with fixed retention to prevent one case of instability: approximately 5 patients
Confidence Interval: Maxilla OR 4.37 (95% CI 1.74-10.98); Mandible OR 14.35 (95% CI 3.24-63.56) for moderate-to-severe instability with removable retention
Clinical Application
Fixed retainers require specialist placement and monitoring; CAD/CAM and robotic fabrication may have limited availability Relevant to Australian orthodontic practice; fixed retainers not typically PBS-funded but may be cost-effective long-term; aligns with ANZAOS retention guidelines Post-orthodontic patients requiring retention, particularly those at higher risk of relapse
Abstract
OBJECTIVES: To evaluate three-dimensional anterior tooth position changes during orthodontic retention and to compare the effectiveness of three distinct fixed retainer fabrication designs including robotically bent retainers alongside with removable retainers. MATERIALS AND METHODS: This retrospective cohort study included 113 patients (226 dental arches; mean retention period 1.3 ± 0.6 years). Combined fixed lingual plus removable retention (group 1, n = 148 arches) comprised CAD/CAM Memotain, conventional multistranded stainless-steel (Twistflex), and robotically bent retainers; group 2 (n = 78 arches) received removable retention only. Digital model superimposition using a three-dimensional tooth-specific coordinate system quantified rotational and translational tooth movements, Little's Irregularity Index (LII), transverse arch widths, and bonding failures. RESULTS: Combined fixed and removable retention showed higher stability than removable-only retention (55% vs. 33% stable arches). Removable retention increased the odds of moderate-to-severe instability (maxilla OR 4.37, 95% CI 1.74-10.98; mandible OR 14.35, 95% CI 3.24-63.56), whereas fixed lingual retention was protective (maxilla OR 0.23, 95% CI 0.09-0.58; mandible OR 0.07, 95% CI 0.02-0.31). Instability mainly involved canine rotations and vertical translations. Robotically bent and CAD/CAM Memotain retainers showed the lowest movement magnitudes and variability, with minimal LII increases. Intercanine and intermolar widths remained stable across fixed retainers. Bonding failures (25%) strongly predicted severe instability. CONCLUSIONS: Three-dimensional tooth movements during retention mainly involve canine rotations and vertical translations. All fixed retainer designs (Twistflex, CAD/CAM-fabricated, and robotically bent) provided greater stability than removable-only retention. CLINICAL RELEVANCE: All fixed retainer designs require regular monitoring of bonding integrity; digitally fabricated and robotically bent retainers demonstrated marginally lower dimensional variability, which may be clinically relevant over longer observation periods.
References
- 1.Köck, J., Lang, F., Niederau, C., Rizk, M., Al-Sakati, H., Lang, N., Wolf, M., & Knaup, I. (2026). Three-dimensional stability during orthodontic retention: A comparative analysis of conventional, CAD/CAM-fabricated, and robotically bent fixed retainers versus removable appliances. Clinical Oral Investigations. https://doi.org/10.1002/14651858.CD002283.pub5
Related Research
Acta odontologica Scandinavica
Predicting gingival embrasure risk after invisible orthodontics using multimodal data and machine learning
23 July 2026
Clinical oral investigations
Predicting occlusal force distribution from intraoral scans using deep learning: a pilot study
7 July 2026
Clinical oral investigations
Temporal dynamics of human biomarkers of orthodontically-induced root resorption: A systematic review
26 June 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service