Sonographic optic nerve sheath diameter measurement for detecting intracranial hypertension in a suspected population: a systematic review and meta-analysis of diagnostic thresholds and influencing factors
Clinical Snapshot
PICO Framework
| P — Population | Patients with suspected intracranial hypertension requiring ICP assessment |
| I — Intervention | Sonographic optic nerve sheath diameter (ONSD) measurement |
| C — Comparator | Invasive intracranial pressure monitoring (reference standard) |
| O — Outcomes | Diagnostic accuracy (sensitivity, specificity, likelihood ratios) for detecting ICP >20 mmHg/cmH2O |
Bottom Line
This well-conducted systematic review and meta-analysis demonstrates that sonographic optic nerve sheath diameter measurement is a valuable non-invasive screening tool for detecting intracranial hypertension. An ONSD threshold of ≥5.1mm shows good diagnostic accuracy (specificity 88.4%, LR+ 6.5) when compared to invasive ICP monitoring. Multiplanar measurement techniques and experienced operators significantly improve diagnostic performance, reducing missed diagnoses by 50%. The technique shows particular promise in nontraumatic brain injury cases. While external validation through multicenter studies is needed, ONSD measurement represents a practical bedside assessment tool for emergency and critical care clinicians when invasive monitoring is unavailable. The findings support its use as a supplementary screening method rather than a replacement for invasive monitoring in definitive ICP management decisions.
Key Findings
P Value: p < 0.001 for multiplanar assessment improvement
Effect Size: CDEI 0.82 (composite diagnostic effectiveness index)
Primary Outcome: Diagnostic accuracy of sonographic ONSD for detecting intracranial hypertension
Nnt Or Sensitivity: Sensitivity 91.9% (nontraumatic), Specificity 88.4%, LR+ 6.5, LR- 0.1
Confidence Interval: 95% CI: 0.79-0.85
Clinical Application
Highly feasible as bedside ultrasound technique, requires trained operators and standardized protocols for optimal accuracy Relevant to Australian emergency and critical care practice, aligns with ACEM guidelines for point-of-care ultrasound, no specific PBS or TGA considerations for ultrasound technique Patients with suspected intracranial hypertension in emergency departments and intensive care units where invasive ICP monitoring is unavailable or contraindicated
Abstract
OBJECTIVES: In this study, we aimed to assess the clinical efficacy of sonographic optic nerve sheath diameter (ONSD) measurements for detecting intracranial hypertension (ICH). Our objectives included evaluating its diagnostic precision compared with invasive intracranial pressure (ICP) monitoring; exploring potential sources of heterogeneity, such as measurement technique (multi vs. single-planar), population demographics (Asian vs. non-Asian), and major etiologies; and determining validated thresholds for prompt bedside ICP assessment in acute neurological crises. DATA SOURCES: We comprehensively searched eight databases, including four in English (PubMed, Web of Science, MEDLINE®, and Embase) and four in Chinese (China National Knowledge Infrastructure [CNKI], Wanfang, VIP, and SinoMed). The search covered literature published from the inception of the databases up to May 31, 2025. STUDY SELECTION: This review includes prospective, retrospective, and case-control studies that assess the efficacy of sonographic ONSD measurement for detecting ICH, defined as an ICP exceeding 20 mm Hg, 20 cmH2O, 25 cmH2O with invasive ICP measurement as the gold standard. DATA EXTRACTION: X.T. and Q.T. independently screened the studies and assessed the risk of bias using the QUADAS-2 tool. STATISTICAL ANALYSIS: Diagnostic accuracy was pooled using a bivariate random-effects model to generate summary receiver operating characteristic (SROC) curves. Subgroup analyses of the measurement technique, study population, and etiology were conducted. Publication bias was assessed using Deeks' test. DATA SYNTHESIS: The decision tree analysis revealed that an ONSD ≥ 5.1 mm is the critical diagnostic threshold for detecting intracranial hypertension. The regression tree model indicated a range of CDEI values from 0.64 to 0.95, with a root node value of 0.82 (95% CI: 0.79-0.85). The incorporation of a multiplanar assessment significantly enhanced the prediction of favorable outcomes (CDEI > 0.85; p < 0.001). Moreover, compared with a 20 mmHg threshold, a 25 cmH₂O threshold resulted in greater specificity (88.4% vs. 82.9%) and a higher positive likelihood ratio (LR+ 6.5 vs. 5.0). The utilization of multiplane techniques and experienced operators notably improved diagnostic accuracy, leading to a 50% reduction in missed diagnoses (LR- 0.1). Nontraumatic brain injury cases exhibited superior sensitivity (91.9% vs. 85.2%) and a 107% higher diagnostic odds ratio (63.3 vs. 30.5) than traumatic brain injury cases did. CONCLUSIONS: Findings from this study suggest that an ONSD threshold ≥ 5.1 mm is a promising diagnostic marker for elevated ICP (> 20 cmH₂O/mmHg or acute etiology), although external validation is needed. A multiplane evaluation improves its predictive accuracy for favorable outcomes. The developed decision model supports the use of sonographic ONSD measurement as a supplementary screening tool in emergency and critical care, particularly when invasive monitoring is unavailable. Additionally, an ONSD of approximately 6.0 mm is a potential prognostic indicator for unfavorable outcomes, highlighting a key area for future research. These findings can only be applied after their validation through multicenter studies and the establishment of standardized measurement protocols.
References
- 1.Wang, X., Wen, Y., Tong, X., & Tang, Q. (2026). Sonographic optic nerve sheath diameter measurement for detecting intracranial hypertension in a suspected population: a systematic review and meta-analysis of diagnostic thresholds and influencing factors. Journal of Neurology. https://doi.org/10.3969/j.issn.1002-1949.2016.11.006
Related Research
Journal of critical care
Artificial intelligence and computerized decision support in adult intensive care: A systematic review of randomized controlled trials
3 Aug 2026
Journal of pediatric surgery
Interpretable deep learning model for pediatric strangulated small bowel obstruction on CT: A multicenter study
3 Aug 2026
Telemedicine journal and e-health : the official journal of the American Telemedicine Association
Application of Telehealth and Artificial Intelligence in Military Health Care: A Promising Combination for the Future
3 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service