Relative apical sparing of left ventricular longitudinal strain for the diagnosis of cardiac amyloidosis: a systematic review and meta-analysis
Clinical Snapshot
PICO Framework
| P — Population | Patients with suspected or confirmed cardiac amyloidosis and controls without cardiac amyloidosis |
| I — Intervention | Relative apical sparing (RELAPS) pattern assessment using speckle-tracking echocardiography |
| C — Comparator | Standard diagnostic methods or controls without cardiac amyloidosis |
| O — Outcomes | Diagnostic accuracy measures including sensitivity, specificity, area under ROC curve, and diagnostic odds ratio |
Bottom Line
This meta-analysis of 41 studies demonstrates that relative apical sparing (RELAPS) on speckle-tracking echocardiography provides moderate diagnostic accuracy for cardiac amyloidosis with good specificity (83.1%) but modest sensitivity (65.9%). The diagnostic performance varies significantly by echocardiography software platform, with TomTec showing substantially lower sensitivity (31.1%) compared to GE EchoPAC (70.4%). While RELAPS may serve as a useful adjunctive tool in the diagnostic workup of suspected cardiac amyloidosis, particularly for ruling in disease given its good specificity, it should not be relied upon as a standalone screening test due to its limited sensitivity. The significant software-dependent variation highlights the critical need for standardised measurement protocols and pre-specified cut-off values before widespread clinical implementation. Clinicians should interpret RELAPS results within the broader clinical context and consider the specific echocardiography platform used.
Key Findings
P Value: Software comparison p<0.001 for sensitivity difference
Effect Size: AUC-ROC 0.818
Primary Outcome: Diagnostic accuracy of RELAPS for cardiac amyloidosis detection
Nnt Or Sensitivity: Sensitivity 65.9%, Specificity 83.1%, Diagnostic Odds Ratio 9.54 (95% CI 7.41-12.10)
Confidence Interval: Sensitivity 65.9% (95% CI 59.2-72.0%), Specificity 83.1% (95% CI 78.5-86.8%)
Clinical Application
Requires speckle-tracking echocardiography capability and trained operators, with software-specific considerations for interpretation Relevant to Australian cardiology practice where speckle-tracking echocardiography is available in major centres. May complement existing diagnostic pathways but software standardisation needed for consistent implementation across Australian healthcare systems Patients with suspected cardiac amyloidosis undergoing echocardiographic evaluation, particularly those with heart failure and preserved ejection fraction
Abstract
BACKGROUND: Cardiac amyloidosis (CA) is underdiagnosed due to non-specific clinical and echocardiographic features. This systematic review and meta-analysis evaluated the diagnostic accuracy of the left ventricular relative apical sparing (RELAPS) pattern on speckle-tracking echocardiography. METHODS: A literature search of PubMed, Scopus and Cochrane was conducted through August 2025. RELAPS was defined as the average apical longitudinal strain divided by the sum of average basal and average middle left ventricular longitudinal strains. Diagnostic accuracy was assessed using a bivariate random-effects model. Subgroup analyses by CA subtype and echocardiogram software, and meta-regression for clinical variables, were performed. Optimal cut-offs were determined by maximising the Youden index. Analyses were conducted in R V.4.4.1. RESULTS: Forty-one studies (3473 CA; 4525 comparators) were included. Pooled analysis yielded an area under the receiver operating characteristic curve (AUC-ROC) of 0.818, with sensitivity 65.9% (95% CIs 59.2% to 72.0%) and specificity 83.1% (CI 78.5% to 86.8%). The diagnostic oods ratio (DOR) was 9.54 (CI 7.41 to 12.10). In subtype analyses, immunoglobulin light chains (AL-CA) showed AUC-ROC 0.876, sensitivity 59.8% (CI 41.1% to 76.0%) and specificity 92.7% (CI 83.6% to 96.9%); transthyretin (ATTR-CA) showed AUC-ROC 0.822, sensitivity 63.8% (CI 51.2% to 74.8%) and specificity 84.4% (CI 76.7% to 89.9%), with no significant differences between subtypes (sensitivity p=0.760; specificity p=0.172). Three echocardiography software systems were evaluated. GE EchoPAC (26 studies) achieved an AUC-ROC of 0.822 (sensitivity 70.4% (CI 64.1% to 76.0%), specificity 81.2% (CI 75.7% to 85.7%)). Philips QLAB (four studies) performed comparably (AUC-ROC 0.904; sensitivity 67.6% (CI 31.2% to 90.6%), specificity 92.7% (CI 73.6% to 98.3%)). In contrast, TomTec (four studies) had an AUC-ROC of 0.806, but its sensitivity (31.1% (CI 9.4% to 66.3%)) was significantly lower than GE EchoPAC's (p<0.001), despite a similar specificity (93.6% (CI 78.8% to 98.3%)). CONCLUSION: RELAPS provides moderate diagnostic accuracy for identifying CA, with good specificity and modest sensitivity. Performance varies by analysis software and threshold, underscoring the need for standardised measurement and prespecified cut-offs.
References
- 1.Ahmad, O., Khan, M. I., Omer, M. H., Alzahrani, T., Janjua, M., Echahidi, Z., Kharabsheh, S. M., Tournoux, F., AlSergani, H., Damy, T., Lairez, O., Vieira, R. J., & Mohty, D. (2026). Relative apical sparing of left ventricular longitudinal strain for the diagnosis of cardiac amyloidosis: a systematic review and meta-analysis. Open Heart, 13(1), e004143. https://doi.org/10.1136/openhrt-2026-004143
Related Research
Bioelectrochemistry (Amsterdam, Netherlands)
From data to diagnosis: A comprehensive review of machine learning-driven wearable sensors in healthcare.
2 Aug 2026
Ultrasound in medicine & biology
A Systematic Review: The Application of Attention Mechanisms in Medical Ultrasound Image Processing
2 Aug 2026
Journal of the American Medical Informatics Association : JAMIA
Explainable machine learning in healthcare: methods, interpretation, and applications for clinical research
2 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service