Research AppraisalRandomised Controlled Trial

Pulsed Field Ablation vs Standard Radiofrequency Ablation for Typical Atrial Flutter: ADVANTAGE AF Trial Substudy

Journal of the American College of CardiologyGerstenfeld, Edward P, Schmidt, Boris, Natale, Andrea et al.14 Apr 2026DOI

Clinical Snapshot

60CEBM
Evidence: ModerateRandomised Controlled Trial

PICO Framework

P — PopulationPatients with persistent atrial fibrillation requiring cavotricuspid isthmus (CTI) ablation for typical atrial flutter during AF ablation procedures
I — InterventionBipolar linear pulsed field ablation (PFA) for CTI ablation with nitroglycerin pretreatment
C — ComparatorStandard irrigated radiofrequency ablation (RFA) for CTI ablation
O — OutcomesPrimary: acute CTI conduction block; Secondary: CTI ablation time, safety events, coronary artery spasm

Bottom Line

This ADVANTAGE AF substudy suggests that bipolar linear pulsed field ablation for cavotricuspid isthmus ablation achieves similar efficacy to radiofrequency ablation (98.6% vs 100% acute block) with significantly shorter procedure times (5 vs 14 minutes). However, this was not a randomised comparison but rather sequential phases of a larger trial, limiting the strength of conclusions. The PFA group required additional coronary safety protocols including nitroglycerin pretreatment, which successfully prevented coronary spasm. While the technology shows promise for improving procedural efficiency without compromising safety or efficacy, the non-randomised design and differential co-interventions between groups warrant cautious interpretation. Australian electrophysiologists should await randomised controlled trial data before widespread adoption, though the efficiency gains may be clinically meaningful in high-volume centres.

Evidence: Moderate

Key Findings

  • P Value: P = 1.00 for efficacy comparison

  • Effect Size: Non-inferiority demonstrated with 1.4% absolute difference

  • Primary Outcome: Acute CTI conduction block: RFA 100% (50/50) vs PFA 98.6% (139/141)

  • Nnt Or Sensitivity: Procedure time reduction: median 9 minutes shorter with PFA (5 vs 14 minutes, P = 0.001)

  • Confidence Interval: Not reported in abstract

Clinical Application

Requires specialised PFA technology and established coronary safety protocols with vasopressor/nitroglycerin pretreatment Technology likely to be adopted in major Australian EP centres; TGA approval status unclear; potential PBS implications for procedure efficiency gains Patients undergoing AF ablation with concurrent typical atrial flutter requiring CTI ablation in Australian electrophysiology centres

Abstract

BACKGROUND: ADVANTAGE AF examined the safety and efficacy of pulsed field ablation (PFA) to treat persistent atrial fibrillation (AF). During AF ablation, typical atrial flutter (AFL) is commonly treated with cavotricuspid isthmus (CTI) ablation. OBJECTIVES: Adjunctive CTI ablation in ADVANTAGE AF was performed with radiofrequency ablation (RFA; phase 1) or bipolar linear PFA (phase 2). Here, we compared lesion characteristics, CTI ablation efficacy, and safety between the ablation modalities. METHODS: A preclinical study assessed lesion dimensions with a novel 2.0 kV bipolar linear PFA catheter. In ADVANTAGE AF, after AF ablation with a pentaspline PFA catheter, CTI ablation was performed: in phase 1 with irrigated RFA, and in phase 2 with the linear PFA catheter (Farapoint). Before PFA CTI ablation ,patients were treated with a vasopressor bolus followed by high-dose intravenous nitroglycerin. RESULTS: Preclinical assessment showed lesion depth increasing at higher field strength and plateauing after 2 applications. In ADVANTAGE AF, 50 and 141 patients received CTI ablation with RFA and PFA, respectively. Patient characteristics across the 2 cohorts were similar (RFA vs PFA). Acute CTI conduction block was similar between techniques (50 of 50 RFA [100%] vs 139 of 141 PFA [98.6%]; P = 1.00). PFA was associated with a shorter CTI ablation time (median: RFA 5 min [Q1-Q3: 4-8 min] vs 14 min [Q1-Q3: 9-19 min]; P = 0.001). RFA and PFA had similar safety event rates (RFA 2.0% vs PFA 2.1%; P = 0.96). With the use of nitroglycerin pretreatment, there was no clinical manifestation of coronary artery spasm with PFA. CONCLUSIONS: This subanalysis of ADVANTAGE AF extends the primary results by allowing comparison of bipolar linear PFA and RF ablation for CTI, integrating preclinical lesion modeling with clinical dosing, and establishing a standardized reliable coronary safety protocol. Although not randomized comparisons, these findings suggest that CTI ablation with a linear PFA catheter is associated with safety and efficacy similar to RF ablation and greater efficiency. (A Prospective Single Arm Open Label Study of the FARAPULSE Pulsed Field Ablation System in Subjects With Persistent Atrial Fibrillation [ADVANTAGE AF; NCT05443594]).

References

  1. 1.Gerstenfeld, E. P., Schmidt, B., Natale, A., Nair, D., Saliba, W., Verma, A., Sommer, P., Metzner, A., Dewland, T. A., Moss, J. D., Amin, A., Champagne, J., Cuoco, F., Hounshell, T., Issa, Z., Turagam, M., Brose, R., Schwartz, T., Raybuck, J. D., Garlitski, A., Mansour, M., & Reddy, V. Y. (2026). Pulsed field ablation vs standard radiofrequency ablation for typical atrial flutter: ADVANTAGE AF trial substudy. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2025.12.081
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service