Performance of large language models conducting systematic review tasks in prosthodontics.
Clinical Snapshot
PICO Framework
| P — Population | Systematic review tasks within the domain of prosthodontics, using a corpus of 59 articles for full-text screening and 31 articles for data extraction identified via a comprehensive database search (December 2024) |
| I — Intervention | Four large language models (GPT-4, Gemini, Claude, and Elicit) applying a 3-pronged prompting strategy (persona-based initialisation, few-shot learning, structured PICO criteria) to perform full-text screening, data extraction, and risk of bias assessment |
| C — Comparator | Expert human assessments serving as the reference standard for accuracy, precision, F1-score, sensitivity, specificity, data extraction quality scoring (0–5 scale), and Cohen kappa for risk of bias agreement |
| O — Outcomes | Accuracy, precision, F1-score, sensitivity, specificity (full-text screening); data extraction quality (median score 0–5); risk of bias agreement (Cohen kappa); temporal reliability across three time points (0, 15, and 30 days) |
Bottom Line
This benchmarking study evaluates four commercially available large language models — GPT-4, Gemini, Claude, and Elicit — across three core systematic review tasks in prosthodontics: full-text screening, data extraction, and risk of bias assessment. The findings are cautiously encouraging for data extraction, where GPT-4 achieved near-perfect median scores, and for full-text screening, where all models maintained sensitivity above 90%. However, risk of bias agreement with human experts was highly variable (55%–90%), and statistically significant inter-model differences emerged for specific sub-tasks. The temporal reliability design is a methodological strength, though model versioning during the study period is a confounding concern. Critical limitations include the small corpus size, restriction to a single dental specialty, absence of confidence intervals, no GRADE assessment, and an incompletely described human reference standard. The authors appropriately conclude that human oversight remains essential. For Australian dental researchers, these tools are accessible but should be treated as adjuncts — not replacements — for trained reviewers. Independent local validation across broader dental and medical specialties is needed before LLM-assisted SR workflows can be recommended with confidence.
Key Findings
P Value: P=.04 for labelling and modelling tasks at Week 1 (Kruskal-Wallis with Dunn post hoc); no other significant differences reported across time points
Effect Size: Inter-model performance differences were statistically significant only for labelling and modelling sub-tasks during Week 1 (P=.04); no significant differences were detected at Weeks 2 or 4, suggesting relative temporal stability for most tasks
Primary Outcome: Full-text screening performance: Claude achieved the highest sensitivity (97%) with 86% accuracy and 87% F1-score; all four models maintained sensitivity above 90%. Data extraction: GPT-4 consistently achieved median scores of 5.0/5.0; Claude and Gemini showed similar capabilities. Risk of bias assessment: agreement with expert judgements ranged from 55% to 90% across different criteria.
Nnt Or Sensitivity: Sensitivity (full-text screening): Claude 97%, all models >90%. Specificity: not explicitly reported in abstract. Cohen kappa (risk of bias): range 55%–90% across criteria — indicating moderate to substantial agreement at best, with some criteria showing only poor-to-moderate agreement
Confidence Interval: Not reported
Clinical Application
GPT-4, Gemini, and Claude are commercially accessible via subscription or API in most high-income countries. Elicit is a dedicated research tool with free and paid tiers. Implementation requires structured prompting expertise and mandatory human oversight at all SR stages. The temporal reliability data (three time points) suggest that outputs should be re-verified if significant time elapses between LLM query and manuscript submission, given potential model updates. All four LLMs evaluated are accessible to Australian dental researchers and clinicians. The Australian Dental Association (ADA) and the Dental Board of Australia have not yet issued formal guidance on LLM use in research workflows. The NHMRC's 2022 guidelines on systematic reviews do not address LLM-assisted evidence synthesis. Australian dental schools and the Cochrane Oral Health Group would benefit from local validation studies before adopting LLM-assisted SR workflows. No PBS or TGA implications apply directly, though TGA-regulated dental devices and materials are common subjects of prosthodontic systematic reviews, making accurate data extraction and risk of bias assessment clinically consequential. Dental and prosthodontic researchers conducting systematic reviews who are considering LLM-assisted workflows for full-text screening, data extraction, or risk of bias assessment. Applicable to academic dental institutions, postgraduate research programmes, and evidence synthesis teams in oral health.
Abstract
STATEMENT OF PROBLEM: Systematic reviews (SRs) are time-consuming and resource-intensive processes. Whether large language models (LLMs) can improve the process is unclear. PURPOSE: The purpose of this study was to evaluate the accuracy and reliability of 4 LLMs (GPT-4, Gemini, Claude, and Elicit) in performing SR tasks (full-text screening, data extraction, and risk of bias assessment) at 3 different sequential periods of time (0, 15, and 30 days). MATERIAL AND METHODS: A comprehensive systematic search was conducted across 5 databases in December 2024, with 59 articles evaluated for screening (2 used for pilot) and 31 for data extraction (2 used for pilot). A 3-pronged prompting strategy was used, including persona-based initialization, few-shot learning, and structured population, intervention, control, outcome (PICO) criteria. Performance was assessed through 3 repeated evaluations at 2-week intervals by measuring accuracy and reliability using standard metrics (accuracy, precision, F1-score, sensitivity, and specificity) against expert assessments, data extraction quality on a 0 to 5 scale, and risk of bias agreement via the Cohen kappa, with statistical analysis using Kruskal-Wallis and Dunn post hoc tests (α=.05). RESULTS: In full-text screening, Claude achieved the highest sensitivity at 97%, while Claude and Elicit both showed strong overall performance with 86% accuracy and 87% F1-scores. All models maintained sensitivity above 90%. For data extraction, GPT-4 consistently performed best with median scores of 5.0, while Claude and Gemini showed similar capabilities. Significant differences only appeared in labeling and modeling tasks during Week 1 (P=.04). Risk of bias assessment agreement with experts varied from 55% to 90% across different criteria. CONCLUSIONS: LLMs show potential for SR efficiency (especially for data extraction) but require human oversight because of variable performance across models and tasks.
References
- 1.Rokhshad, R., Motie, P., Shirani, M., Sameie, A., & Revilla-León, M. (2026). Performance of large language models conducting systematic review tasks in prosthodontics. The Journal of Prosthetic Dentistry. Advance online publication. https://doi.org/10.1016/j.prosdent.2026.02.009
Related Research
International dental journal
Deep Learning Based on Swin-Transformer and 3D U-Net: Implant Three-Dimensional Position Planning
2 Aug 2026
Journal of prosthodontic research
Peri-implant soft-tissue responses to tooth-colored abutment materials: A systematic review.
14 July 2026
BMC oral health
Accuracy of virtual facebow compared to conventional facebow: a systematic review
13 July 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service