OptiDON-Guard: An Ensemble Model for Identification of Dysthyroid Optic Neuropathy Using Optical Coherence Tomography Angiography
Clinical Snapshot
PICO Framework
| P — Population | 346 thyroid eye disease patients with or without dysthyroid optic neuropathy from two institutions |
| I — Intervention | Machine learning ensemble model (OptiDON-Guard) using optical coherence tomography angiography features |
| C — Comparator | Individual machine learning models and clinical assessment |
| O — Outcomes | Diagnostic accuracy metrics (AUC, sensitivity, specificity, accuracy, precision) for identifying dysthyroid optic neuropathy |
Bottom Line
This dual-center study developed OptiDON-Guard, an ensemble machine learning model using optical coherence tomography angiography to identify dysthyroid optic neuropathy in 346 thyroid eye disease patients. The model achieved good diagnostic performance with AUC values of 0.872 (internal validation) and 0.854 (external validation). However, several methodological concerns limit confidence in these results: the reference standard for DON diagnosis is not clearly defined, confidence intervals are not provided, and blinding procedures are not described. While the dual-center design and external validation are strengths, the clinical utility and impact on patient management remain unclear. The high specificity (97.9% internal, 84.2% external) suggests potential value as a rule-in test, but the moderate sensitivity (66.7-76.7%) indicates significant false-negative rates. Before clinical implementation, this tool requires validation against clearly defined reference standards, assessment of clinical utility, and regulatory approval. The interpretable nature using SHAP analysis is promising for clinical acceptance.
Key Findings
P Value: Not reported
Effect Size: AUC 0.872 (internal validation), 0.854 (external test)
Primary Outcome: Diagnostic accuracy for identifying dysthyroid optic neuropathy
Nnt Or Sensitivity: Sensitivity 66.7% (internal), 76.7% (external); Specificity 97.9% (internal), 84.2% (external)
Confidence Interval: Not reported
Clinical Application
Requires OCTA imaging capability and machine learning infrastructure, which may limit accessibility in some settings OCTA is available in major Australian ophthalmology centers. Would need TGA approval for clinical use. Could complement existing RACGP thyroid eye disease management guidelines Patients with thyroid eye disease requiring assessment for dysthyroid optic neuropathy
Abstract
PURPOSE: To explore the value of machine learning models based on optical coherence tomography angiography (OCTA) in identifying dysthyroid optic neuropathy (DON). METHODS: A retrospective, dual-center, cross-sectional study was conducted involving 346 thyroid eye disease patients (with/without DON) from two institutions. Participants underwent ophthalmic examinations, including OCTA scans centered on the macula and optic nerve head. The OCTA data from Center 1 were split into a training set and an internal validation set, while the data from Center 2 served as an external test set. Features were extracted from OCTA images, and a wrapper-based feature selection strategy identified the optimal subset. A two-tiered stacking modeling framework was used, incorporating baseline model construction, data augmentation using pseudo-labeling, and ensemble integration. Model performance (area under the curve [AUC], accuracy, sensitivity, specificity, precision) was evaluated alongside receiver operating characteristic, calibration, and decision curve analyses. Additionally, the SHapley Additive exPlanation method was used to interpret feature contributions. RESULTS: The ensemble model, OptiDON-Guard, demonstrated superior performance to individual models on both internal validation and external test sets. In the internal validation set, it achieved an AUC of 0.872, accuracy of 0.943, sensitivity of 0.667, specificity of 0.979, and precision of 0.943. In the external test set, it maintained strong performance with an AUC of 0.854, accuracy of 0.816, sensitivity of 0.767, specificity of 0.842, and precision of 0.854. CONCLUSIONS: The OptiDON-Guard is a reliable, interpretable, and clinically applicable tool for identifying DON. TRANSLATIONAL RELEVANCE: The OptiDON-Guard offers a valuable clinical tool to enhance the diagnostic precision of DON.
References
- 1.Zhang, Y., Mao, Y., Zheng, J., Wang, L., Wu, M., Zhao, J., Li, Z., Liu, W., Zhou, S., Wan, S., Tu, Y., Wu, W., & Yan, W. (2026). OptiDON-Guard: An ensemble model for identification of dysthyroid optic neuropathy using optical coherence tomography angiography. Translational Vision Science & Technology, 15(4), 4. https://doi.org/10.1167/tvst.15.4.4
Related Research
Indian journal of ophthalmology
Internet of things in assistive technology for people with visual impairment: A scoping review
1 Aug 2026
BMJ open ophthalmology
Screening for diabetic retinopathy with artificial intelligence in a primary care setting: a comparative cost analysis
1 Aug 2026
Science advances
Multispectral infrared-to-full-color upconversion expanding human vision
1 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service