Research AppraisalSystematic Review

Limus- Versus Paclitaxel-Coated Balloons for In-Stent Restenosis Treatment: A Systematic Review and Study-Level Meta-Analysis of Randomized Controlled Trials

The American journal of cardiologySuruagy-Motta, Ricardo F O, Carvalho, Pedro E P, da Silva, Leonardo Dexheimer et al.15 June 2026DOI

Clinical Snapshot

95CEBM
Evidence: StrongSystematic Review

PICO Framework

P — PopulationPatients with coronary in-stent restenosis (ISR)
I — InterventionLimus-coated balloons (LCB, typically sirolimus or biolimus)
C — ComparatorPaclitaxel-coated balloons (PCB)
O — OutcomesPrimary: clinically driven target lesion revascularization; Secondary: target lesion failure, all-cause mortality, myocardial infarction, stent thrombosis, MACE, angiographic outcomes (late lumen loss, minimal lumen diameter)

Bottom Line

This well-conducted meta-analysis of six RCTs (1,038 patients) demonstrates that paclitaxel-coated balloons provide superior efficacy compared to limus-coated balloons for treating in-stent restenosis. PCB reduced clinically driven target lesion revascularization by 48% (RR 1.48, 95% CI 1.02-2.14, p=0.04) with low heterogeneity. Safety profiles were comparable between platforms, with no significant differences in mortality, myocardial infarction, or stent thrombosis. Angiographic outcomes showed similar late lumen loss between groups, though with high heterogeneity. The absolute benefit translates to preventing approximately one repeat revascularization per 20-25 patients treated with PCB versus LCB. These findings support current preference for paclitaxel-coated balloons as first-line therapy for coronary in-stent restenosis, providing modest but statistically significant reduction in repeat interventions without compromising safety.

Evidence: Strong

Key Findings

  • P Value: 0.04

  • Effect Size: RR: 1.48 (95% CI: 1.02 to 2.14)

  • Primary Outcome: Clinically driven target lesion revascularization significantly higher with LCB vs PCB

  • Nnt Or Sensitivity: NNH approximately 20-25 patients (estimated from RR and baseline risk)

  • Confidence Interval: 1.02 to 2.14

Clinical Application

Both balloon types available in Australian interventional cardiology practice Relevant to Australian interventional cardiologists; both PCB and LCB available through PBS for appropriate indications; aligns with CSANZ guidelines for ISR management Patients with coronary in-stent restenosis requiring percutaneous intervention

Abstract

Drug-coated balloons are the preferred treatment for in-stent restenosis (ISR), avoiding the need for a second metallic layer. While both paclitaxel-coated balloons (PCB) and limus-coated balloons (LCB, typically sirolimus or biolimus) are used, direct comparative evidence is limited, particularly regarding their long-term angiographic efficacy and clinical safety. We conducted a systematic review and study-level meta-analyzis of studies comparing LCB with PCB for coronary ISR. A comprehensive search was performed across PubMed, Embase, Cochrane, Scopus, Web of science for randomized controlled trials. Outcomes were compared using risk ratios (RR) for categorical data and mean differences for continuous data in a random-effects model. Heterogeneity was assessed using the I2 statistic. Six randomized controlled trials involving 1,038 patients were included (552 in the LCB group and 481 in the PCB group). Compared with PCB, LCB were associated with a significantly higher risk of clinically driven target lesion revascularization (RR: 1.48; 95% CI: 1.02 to 2.14; p = 0.04; I2 = 0%) and target lesion failure (RR: 1.19; 95% CI: 0.87 to 1.62; p = 0.27; I2 = 0%). In contrast, both platforms demonstrated no differences in all-cause mortality (RR: 0.98; p = 0.96), myocardial infarction (RR: 0.73; p = 0.46), stent thrombosis (RR: 0.66; p = 0.57), or MACE (RR: 1.09; p = 0.58). Angiographic outcomes were comparable, including late lumen loss (mean differences: -0.00 mm; p = 0.65; I2 = 74.7%) and minimal lumen diameter (mean differences: -0.12 mm; p = 0.07). In patients with ISR, PCB reduced repeat revascularization compared with LCB. These data suggest a modest advantage for PCB in preventing restenosis following drug-coated balloon angioplasty for ISR.

References

  1. 1.Suruagy-Motta, R. F., Carvalho, P. E., da Silva, L. D., de Oliveira Oldra, L. G., Pereira, M. S., Silva, L. V., Almeida, L. G., Ferreira, L. C., Pinto, E. L., Pileggi, B., Filho, E. M., Gibson, C. M., & Brilakis, E. S. (2026). Limus- versus paclitaxel-coated balloons for in-stent restenosis treatment: A systematic review and study-level meta-analysis of randomized controlled trials. *The American Journal of Cardiology*, *Advanced online publication*. https://doi.org/10.1016/j.amjcard.2026.03.049
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service