Research Appraisaldiagnostic

Improving confidence in MRI-based auto-segmentation via uncertainty assessment.

Acta oncologica (Stockholm, Sweden)Kallehauge, Jesper Folsted, Ren, Jintao, Lassen-Ramshad, Yasmin11 May 2026DOI

Clinical Snapshot

80CEBM
Evidence: Moderatediagnostic

PICO Framework

P — Population70 brain cancer patients undergoing T1-weighted contrast-enhanced MRI (55 training/validation, 15 testing)
I — InterventionResEncM (residual-encoding variant of nnU-Netv2) for automated organ-at-risk segmentation
C — ComparatorStandard nnU-Netv2 architecture
O — OutcomesGeometric accuracy (Dice similarity coefficient), epistemic uncertainty quantification, Expected Calibration Error (ECE), and ensemble variance

Bottom Line

This study demonstrates that incorporating residual encoding into standard U-Net architecture (ResEncM) significantly improves the reliability and calibration of automated brain organ-at-risk segmentation while maintaining high geometric accuracy. The key clinical advantage lies in better uncertainty quantification, allowing clinicians to identify regions requiring manual review. While geometric performance was comparable between methods, ResEncM's superior calibration makes it more trustworthy for clinical implementation. The small test cohort (n=15) and single-centre design limit immediate generalizability, but the methodology represents an important advance toward confidence-aware automated contouring. For Australian radiation oncology centres, this technology could enhance workflow efficiency while maintaining safety standards, particularly valuable given increasing treatment complexity and workforce pressures. Further validation in larger, multi-centre cohorts is needed before widespread clinical adoption.

Evidence: Moderate

Key Findings

  • P Value: p < 0.05 for uncertainty metrics; p = 0.003 for pituitary DSC; p = 0.018 for chiasm DSC

  • Effect Size: Significantly reduced Expected Calibration Error for optic chiasm, optic tracts, and pituitary

  • Primary Outcome: ResEncM demonstrated significantly lower epistemic uncertainty and ensemble variance across all structures (p < 0.05)

  • Nnt Or Sensitivity: Brainstem DSC > 0.93, hippocampi DSC > 0.81 for both models

  • Confidence Interval: Not explicitly reported

Clinical Application

Requires deep learning infrastructure and MRI-based planning systems; computationally intensive but clinically feasible Highly relevant to Australian radiation oncology centres using MRI-guided radiotherapy; aligns with RANZCR guidelines for precision radiotherapy Brain cancer patients requiring radiotherapy planning with MRI-based organ-at-risk delineation

Abstract

BACKGROUND AND PURPOSE: Accurate delineation of organs of interest (OOIs, also commonly referred to as organs at risk, OARs) is crucial for safe radiotherapy. While deep learning-based segmentation using convolutional neural networks has achieved high geometric accuracy, clinical translation is hindered by overconfident, uncalibrated predictions in anatomically ambiguous regions. Uncertainty quantification and model calibration are prerequisites for safe clinical workflows. This study compared the standard nnU-Netv2 against its residual-encoding variant (ResEncM), hypothesizing that ResEncM would demonstrate superior reliability and calibration while maintaining comparable geometric accuracy. Patient/material and methods: T1-weighted contrast-enhanced MRI scans from 70 brain cancer patients were used (55 training/validation, 15 testing). Ground-truth contours for brainstem, hippocampi, chiasm, optic nerves, optic tracts, and pituitary were delineated per Danish Neuro Oncology Group guidelines. Both architectures were trained using five-fold cross-validation with identical preprocessing. Epistemic uncertainty was quantified using mutual information, and Expected Calibration Error (ECE) was computed within a 10-mm isotropic margin around reference contours. RESULTS: Both models achieved high geometric accuracy (brainstem dice similarity coefficient [DSC] > 0.93, hippocampi DSC > 0.81). No significant geometric differences were found for large structures. ResEncM showed significantly lower DSC for the pituitary (p = 0.003) and chiasm (p = 0.018). However, ResEncM demonstrated significantly lower epistemic uncertainty and ensemble variance across all structures (p < 0.05), and significantly reduced ECE for the optic chiasm, optic tracts, and pituitary. INTERPRETATION: Integrating a deep residual encoder into the standard U-Net framework significantly improves reliability and calibration of automated brain OOI contours while maintaining strong geometric performance. The ResEncM architecture provides a more trustworthy tool for clinical radiotherapy by reliably flagging high-uncertainty voxels, supporting confidence-aware clinical workflows.

References

  1. 1.Kallehauge, J. F., Ren, J., & Lassen-Ramshad, Y. (2026). Improving confidence in MRI-based auto-segmentation via uncertainty assessment. Acta Oncologica, Article 45685. https://doi.org/10.2340/1651-226X.2026.45685
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service