Gamma Knife treatment planning using knowledge-based reinforcement learning
Clinical Snapshot
PICO Framework
| P — Population | Adult patients undergoing Gamma Knife stereotactic radiosurgery for single brain metastases (n=204) or acoustic neuromas (n=71) at a single tertiary centre (Sunnybrook Health Sciences Centre, Toronto, Canada) |
| I — Intervention | Deep reinforcement learning (DRL) agent trained to automatically adjust inverse planning priority weights (slider bars) in the Leksell Gamma Knife Icon inverse planner, using a knowledge-based reward function derived from historical clinical plan metrics |
| C — Comparator | Default slider bar settings in the clinical inverse planner (i.e., standard automated inverse planning without DRL weight optimisation) |
| O — Outcomes | Composite plan quality score derived from four clinical dose-volume metrics (target coverage, selectivity, gradient index, and organ-at-risk dose), benchmarked against historical clinical plans; statistical significance of score differences between DRL agent and default planner |
Bottom Line
This single-centre retrospective proof-of-concept study demonstrates that a deep reinforcement learning agent can be trained to automatically adjust inverse planning weights for Gamma Knife radiosurgery, producing plans with dosimetric quality scores marginally superior to default planner settings for single brain metastases (statistically significant, p=0.0136) and acoustic neuromas (non-significant, p=0.4493). The absolute score differences are small, confidence intervals are not reported, and the composite scoring metric has not been validated against clinical outcomes such as tumour control or toxicity. The knowledge-based reward function is explicitly trained on site-specific historical plans, limiting direct generalisability to other institutions without retraining. Manufacturer co-authorship (Elekta) warrants transparency scrutiny. For Australian Gamma Knife centres, this technology is not yet clinically deployable — prospective validation, TGA regulatory consideration, and ACPSEM physics review would be prerequisites. The study represents a methodologically sound early-stage development contribution to radiosurgery planning automation, but clinicians should not interpret the current evidence as supporting clinical implementation. Independent multicentre validation with patient outcome data is required before this approach can be recommended for routine practice.
Key Findings
P Value: Metastases: p=0.0136 (statistically significant). Acoustic neuromas: p=0.4493 (not statistically significant)
Effect Size: Metastases: DRL agent mean score 3.925 ± 0.130 vs default 3.874 ± 0.147 (absolute difference +0.051). Acoustic neuromas: DRL agent mean score 4.035 ± 0.177 vs default 3.995 ± 0.365 (absolute difference +0.040). Score scale and clinical thresholds not defined in abstract.
Primary Outcome: Composite plan quality score (derived from four dosimetric metrics: target coverage, selectivity, gradient index, and OAR dose) comparing DRL agent plans to default inverse planner slider plans, benchmarked against historical clinical plans
Nnt Or Sensitivity: Not applicable in conventional sense; no NNT, sensitivity/specificity, or hazard ratio reported. No clinical outcome data available to calculate number needed to treat or similar metrics.
Confidence Interval: Not reported for any outcome
Clinical Application
The DRL agent adjusts two priority weight sliders within the existing clinical inverse planner workflow, suggesting low integration burden if embedded within the Leksell planning software. However, clinical deployment would require prospective validation, regulatory approval, and institutional retraining of the model on site-specific historical plans. Planning time savings are not quantified. Clinician oversight protocols for agent-generated plans are not described. Gamma Knife radiosurgery is available at a small number of Australian tertiary centres including St Vincent's Hospital Sydney, Royal Melbourne Hospital, and Princess Alexandra Hospital Brisbane. The Leksell Gamma Knife Icon is the current generation platform used in Australia. TGA approval would be required before clinical deployment of any embedded planning software modification. RANZCR (Royal Australian and New Zealand College of Radiologists) and ACPSEM (Australasian College of Physical Scientists and Engineers in Medicine) guidelines on stereotactic radiosurgery quality assurance would apply. PBS does not directly fund radiosurgery planning software; costs would be absorbed by hospital or state health system budgets. Australian centres considering adoption would need to retrain the model on their own institutional planning data, as the reward function is site-specific. Given the small number of Australian Gamma Knife centres, multicentre data pooling would be necessary to achieve adequate training set sizes, particularly for acoustic neuromas. Patients with single brain metastases or acoustic neuromas undergoing Gamma Knife stereotactic radiosurgery at centres using the Leksell Gamma Knife Icon platform with its proprietary inverse planner. Not yet validated for multi-target metastases, arteriovenous malformations, trigeminal neuralgia, or other Gamma Knife indications.
Abstract
BACKGROUND: Inverse planning is often used for Gamma Knife radiosurgery, allowing clinicians to mathematically specify desired clinical objectives and dose limits. The objectives are controlled by weights that are manually tuned to find the desired trade-off, which varies from case to case. Automation of this process can reduce clinical workload and improve consistency in plan quality. PURPOSE: To train a deep reinforcement learning agent using a reward function that incorporates the clinical metrics from past plans into its scoring criteria. The metric trade-off from the clinical plan is scored higher than all others, guiding the agent to produce plans with similar trade-offs. METHODS: An agent was trained to adjust the two priority weights (i.e., digital slider bars) in the clinical inverse planner. The agent consists of a neural network that receives the metrics and dose distribution of the current plan and the target and organ-at-risk masks as inputs. These methods were demonstrated on a dataset of 204 single-target metastases and a dataset of 71 acoustic neuroma cases. The cases were split into training, validation, and testing sets of size 123/41/40 and 42/14/15 for the metastases and acoustic neuromas, respectively. RESULTS: On the metastases test dataset, the agent achieved a significantly higher (p = 0.0136) average plan score (3.925 ± 0.130) compared to the default slider plans (3.874 ± 0.147). On the acoustic neuromas test dataset, the agent achieved a higher (p = 0.4493) average plan score (4.035 ± 0.177) compared to the default slider plans (3.995 ± 0.365). The higher plan scores are reflected in the four plan quality metrics: the agent's plans, on average, had metrics more similar to the clinical plans, compared to the default slider plans, for both test datasets. CONCLUSIONS: The proposed reward function enabled the agent to learn to find plans that aligned with historical planning decisions. Future work will investigate providing the agent with additional inputs that can explain the variability in planning decisions, which would further improve its performance.
References
- 1.Huynh, C., Ahlgren, B., Zhang, B., Fay, D., Nordström, H., & Ruschin, M. (2026). Gamma Knife treatment planning using knowledge-based reinforcement learning. Medical Physics. https://doi.org/10.1109/TRPMS.2021.3107454
Related Research
Medical physics
Reference-Free large language model agents for physician-guided radiotherapy treatment planning
2 Aug 2026
Cancer medicine
Applications of Artificial Intelligence in Cancer Diagnosis and Treatment
1 Aug 2026
Acta oncologica (Stockholm, Sweden)
User perceptions of machine learning models as decision support for colorectal cancer multidisciplinary team conferences (AID-SIM-2): a qualitative simulation study.
1 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service