External validation of an explainable electrocardiogram-only deep learning algorithm for the prediction of response after cardiac resynchronization therapy
Clinical Snapshot
PICO Framework
| P — Population | 161 patients with heart failure receiving cardiac resynchronization therapy at University of Virginia (external validation cohort) |
| I — Intervention | FactorECG deep learning algorithm using 21 explainable ECG factors |
| C — Comparator | American Heart Association criteria for left bundle branch block; mechanical dyssynchrony indices |
| O — Outcomes | Volumetric nonresponse to CRT (C-statistic, sensitivity, specificity) |
Bottom Line
This external validation study demonstrates that an ECG-based deep learning algorithm (FactorECG) can predict volumetric nonresponse to cardiac resynchronization therapy better than current guideline criteria. The algorithm achieved a C-statistic of 0.67 compared to 0.51 for AHA left bundle branch block criteria in 161 patients from a US center. Performance improved to 0.79 when combined with mechanical dyssynchrony measures. While promising, the moderate discriminative ability and lack of sensitivity/specificity data limit immediate clinical implementation. The approach offers potential for improving patient selection for CRT, but requires larger validation studies with clinical outcome endpoints and defined decision thresholds before routine adoption. The ECG-only approach is attractive for its simplicity and broad applicability in clinical practice.
Key Findings
P Value: Statistically significant (p-value not explicitly reported)
Effect Size: C-statistic 0.67 for FactorECG algorithm vs 0.51 for AHA LBBB criteria
Primary Outcome: Volumetric nonresponse to cardiac resynchronization therapy
Nnt Or Sensitivity: C-statistic improved to 0.79 (95% CI 0.71-0.85) when combined with mechanical dyssynchrony indices
Confidence Interval: 95% CI 0.59-0.76 vs 95% CI 0.41-0.60
Clinical Application
High feasibility as requires only standard 12-lead ECG, though algorithm implementation may require specialized software Relevant to Australian cardiology practice; CRT devices covered under PBS for eligible patients; could inform patient selection and reduce inappropriate implantations Patients with heart failure being considered for CRT implantation
Abstract
BACKGROUND: Cardiac resynchronization therapy (CRT) can improve clinical outcomes in patients with dyssynchronous heart failure, but many patients selected according to the current guidelines do not respond. OBJECTIVE: This study aimed to externally validate an explainable deep learning algorithm (the FactorECG algorithm) for predicting response after biventricular pacing. METHODS: We previously trained a deep learning algorithm on >1 million electrocardiogram (ECG) median beats to learn the underlying generative factors of the ECG and applied it to 1306 patients with CRT from the Netherlands. Using the extracted 21 explainable factors, a model predicting the risk of volumetric nonresponse and poor clinical outcomes was developed. In the present analysis, this model was externally validated in a cohort of 161 patients with CRT from the University of Virginia for volumetric nonresponse only. Subsequently, the added value of clinical and cardiac magnetic resonance imaging-derived predictors was investigated. RESULTS: The original model significantly outperformed American Heart Association criteria for left bundle branch block for the prediction of nonresponse {C-statistic 0.67 (95% confidence interval [CI] 0.59-0.76) vs 0.51 (95% CI 0.41-0.60), respectively}. A refitted FactorECG-based model performed similarly to a model also integrating indices of mechanical dyssynchrony (C-statistic 0.74 [95% CI 0.66-0.82] vs 0.70 [95% CI 0.62-0.77], respectively). A combination of both models improved response prediction (C-statistic 0.79 [95% CI 0.71-0.85]). CONCLUSION: In this external validation study, an explainable ECG-only algorithm for the prediction of nonresponse after CRT device implantation generalized well to a lower-risk population from a different hospital. Adding indices of mechanical dyssynchrony and right ventricular function might be of additional value when evaluating volumetric response.
References
- 1.van de Leur, R. R., Bivona, D. J., Herur, R., van der Harst, P., Meine, M., van Es, R., Bilchick, K. C., & Wouters, P. C. (2026). External validation of an explainable electrocardiogram-only deep learning algorithm for the prediction of response after cardiac resynchronization therapy. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.01.014
Related Research
Bioelectrochemistry (Amsterdam, Netherlands)
From data to diagnosis: A comprehensive review of machine learning-driven wearable sensors in healthcare.
2 Aug 2026
Ultrasound in medicine & biology
A Systematic Review: The Application of Attention Mechanisms in Medical Ultrasound Image Processing
2 Aug 2026
Journal of the American Medical Informatics Association : JAMIA
Explainable machine learning in healthcare: methods, interpretation, and applications for clinical research
2 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service