Evaluation of Exertional Sweat Loss Estimates in Wearable Technology
Clinical Snapshot
PICO Framework
| P — Population | 111 healthy adults (age 40±14 years) participating in running trials under varying conditions |
| I — Intervention | Two commercially available smartwatches for sweat loss estimation |
| C — Comparator | Gold standard criterion measurement based on change in nude body mass pre- and post-exercise |
| O — Outcomes | Accuracy of sweat loss estimates measured by mean absolute error, mean absolute percentage error, concordance correlation coefficient, and Bland-Altman analysis |
Bottom Line
This study demonstrates that while commercially available smartwatches show reasonable correlation with gold standard sweat loss measurements, they exhibit substantial measurement errors (25-33%) that limit their clinical utility for precise hydration management. The devices may serve as useful general tracking tools for recreational athletes but cannot replace laboratory methods when accuracy is critical. For Australian practitioners, these findings suggest wearable devices could support general hydration awareness in community sports settings, but traditional measurement methods remain essential for elite athletes or clinical applications where precise fluid balance monitoring is required. The study's large sample size and real-world testing conditions strengthen the generalisability of these findings to typical exercise scenarios.
Key Findings
P Value: Not reported in abstract
Effect Size: Acceptable correlation (CCC 0.71-0.90) but substantial errors (MAPE 25.38-33.21%)
Primary Outcome: Accuracy of smartwatch sweat loss estimates compared to gold standard body mass change
Nnt Or Sensitivity: Mean absolute percentage error 25.38-33.21% indicating poor precision for clinical use
Confidence Interval: Confidence intervals provided for difference in means (specific values not reported in abstract)
Clinical Application
High feasibility for general population monitoring but limited utility for precise clinical hydration management Relevant for Australian sports medicine practitioners and exercise physiologists, particularly given high participation in outdoor running activities and extreme climate conditions requiring hydration monitoring Active adults engaged in endurance exercise, particularly runners across various fitness levels and environmental conditions
Abstract
BACKGROUND: Wearable technology shows promise for monitoring exertional sweat loss, yet its accuracy requires evaluation. This study evaluated the accuracy of 2 commercially available smartwatches for estimating sweat loss compared with gold standard methods. HYPOTHESIS: Sweat loss values measured via wearable technology will be determined accurate compared with gold standard methods. STUDY DESIGN: Cross-sectional. LEVEL OF EVIDENCE: Level 2. METHODS: A total of 111 participants (age, 40 ± 14 years; height, 171.0 ± 8.9 cm; body mass, 70.8 ± 14.7 kg; VO2max, 46.8 ± 8.7 ml/kg/min) completed up to 4 running trials under varying conditions (indoor/outdoor, distances from 2.5 km to 20 km, and interval runs). Sweat loss estimates from each smartwatch were compared with criterion measurements based on change in nude body mass pre- and postexercise. Validity statistics included tests for error (mean absolute error [MAE], mean absolute percentage error [MAPE]), linearity (Lin's concordance correlation coefficient [CCC], Pearson's [r], and Deming regression), equivalence (CI for difference in means), and Bland-Altman plots for bias assessment. Stratified analyses by sex, weight, and fitness category were also completed, along with a chi-square test of independence. RESULTS: Both devices demonstrated acceptable overall correlation (CCC range, 0.71 to 0.90) but substantial errors in estimating exertional sweat loss (MAPE range, 25.38% to 33.21%). Stratified analyses yielded similar results, with no additional analyses meeting the combined validity thresholds. CONCLUSION: Wearable devices offer a promising and convenient tool for general sweat loss tracking but lack the precision to replace laboratory methods for hydration management. Traditional methods remain essential for the most accurate measurements. CLINICAL RELEVANCE: Wearable devices provide an accessible option for sweat loss monitoring. This study highlights their potential for general tracking while emphasizing the need for laboratory methods when accuracy is critical, ensuring better guidance for hydration strategies in sports performance and health applications.
References
- 1.Carrier, B., Melvin, A. C., Outwin, J. R., Wasserman, M. G., Audet, A. P., Soldes, K. C., Kozloff, K. M., & Lepley, A. S. (2026). Evaluation of exertional sweat loss estimates in wearable technology. Sports Health. https://doi.org/10.1177/19417381251388642
Related Research
The Knee
Artificial intelligence in the management of sports knee injuries: a narrative review.
3 Aug 2026
Archives of orthopaedic and trauma surgery
Shoulder injuries in rugby union: a systematic review and meta-analysis
31 July 2026
Lasers in medical science
Effect of photobiomodulation on trapezius myofascial pain: a randomized, sham-controlled, double-blind clinical trial.
28 July 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service