Research AppraisalSystematic Review

Emerging robotic platforms in partial nephrectomy: a comparative systematic review and network meta-analysis

Journal of robotic surgeryAlmajali, Mohammad N, Darwish, Saba'a, Bani-Ata, Ahmad et al.21 May 2026DOI

Clinical Snapshot

60CEBM
Evidence: WeakSystematic Review

PICO Framework

P — PopulationPatients undergoing robotic-assisted partial nephrectomy (RAPN)
I — InterventionEmerging robotic platforms (Hugo, Hinotori, KangDuo, MP1000)
C — ComparatorEstablished da Vinci robotic systems (Si, Xi, SP)
O — OutcomesOperative time, ischemia time, estimated blood loss, length of hospital stay, R.E.N.A.L. nephrometry scores

Bottom Line

This network meta-analysis of 13 studies (n=2,450) compared perioperative outcomes across robotic platforms for partial nephrectomy. While fixed-effects models suggested shorter operative times for da Vinci SP and Xi systems, substantial heterogeneity (I²>80%) rendered these findings non-significant under random-effects analysis. No meaningful differences were found for blood loss, length of stay, or complexity scores. The evidence remains preliminary due to limited data on emerging platforms, high between-study heterogeneity, and lack of long-term outcomes. Current evidence is insufficient to guide platform selection beyond surgeon familiarity and institutional availability. Australian urologists should await more robust comparative data before considering platform switches, particularly given the established safety profile of da Vinci systems and current TGA approval status.

Evidence: Weak

Key Findings

  • P Value: Not significant under random-effects models

  • Effect Size: da Vinci SP: SMD -0.63 (fixed-effects), Xi: SMD -0.52 (fixed-effects)

  • Primary Outcome: Operative time differences between robotic platforms

  • Nnt Or Sensitivity: P-scores used for platform ranking; clinical significance unclear due to heterogeneity

  • Confidence Interval: SP: 95% CI -0.87 to -0.40; Xi: 95% CI -0.67 to -0.38

Clinical Application

Limited by availability of newer platforms and surgeon experience da Vinci systems widely available in Australian centres; emerging platforms not yet TGA-approved or PBS-funded Patients requiring partial nephrectomy suitable for robotic approach

Abstract

Robotic-assisted partial nephrectomy (RAPN) is the preferred minimally invasive nephron-sparing technique, with outcomes comparable to open and laparoscopic surgery. While most evidence derives from the da Vinci system, newer robotic platforms such as Hugo, Hinotori, KangDuo and MP1000 are emerging. This systematic review and network meta-analysis evaluated perioperative outcomes across available RAPN platforms. A systematic search of PubMed, Cochrane Library, CINAHL, and Scopus identified studies reporting RAPN outcomes across available robotic platforms. Eligible studies included randomized and observational cohorts. Risk of bias was assessed with ROBINS-I. Outcomes included in the analysis operative time (OT), estimated blood loss (EBL), and length of hospital stay (LOS). A frequentist NMA using the "netmeta" R package generated standardized mean differences (SMD) with 95% CIs, and P-scores ranked platform performance. The review was registered on PROSPERO (ID: CRD420251032233). This review was conducted in accordance with PRISMA guidelines. Thirteen studies (n = 2,450) were included. Under fixed-effects model, da Vinci SP (SMD - 0.63, 95% CI - 0.87 to - 0.40) and Xi (-0.52, 95% CI - 0.67 to - 0.38) revealed shorter operative times; however, under random-effects models these differences were not statically significant due to substantial heterogeneity. Heterogeneity (I² ≈ 84%) attenuated these effects. For ischemia time, Hugo RAS (-0.88, 95% CI - 1.45 to - 0.30) and Xi (-0.58, 95% CI - 0.73 to - 0.44) outperformed Si, though differences lost significance under random-effects (I² >90%). No significant differences were found for length of stay, blood loss, or R.E.N.A.L. nephrometry scores, although ranking differences were observed. Preoperative outcomes were revealed a comparable outcome using emerging robotic system with the established system. Favourable trends in operative and ischemia times were showed in some platforms; however, these differences were not vigorous under random-effects models and are limited by substantial heterogeneity. This raised the need for long-term, comparative follow-up studies, as the current evidence remains elementary.

References

  1. 1.Almajali, M. N., Darwish, S., Bani-Ata, A., Alkelani, L., Davis, A. E., Hammad, M., Dobbs, R. W., Lee, D. I., & Shahait, M. (2026). Emerging robotic platforms in partial nephrectomy: a comparative systematic review and network meta-analysis. Journal of Robotic Surgery. https://doi.org/10.1089/end.2022.0600
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service