Research Appraisalother

Dosimetric evaluation of simultaneous multi-energy (2-18 MV) and intensity optimization for IMRT and VMAT.

Biomedical physics & engineering expressRohani, Aliasghar, Guo, Beibei, Zhang, Rui4 May 2026DOI

Clinical Snapshot

85CEBM
Evidence: Moderateother

PICO Framework

P — PopulationThirteen prostate cancer patients requiring radiotherapy
I — InterventionMulti-energy (ME) IMRT and VMAT using simultaneous optimization of 2-5 photon energies (2-18 MV)
C — ComparatorSingle-energy (SE) IMRT and VMAT plans using 6 MV or 10 MV
O — OutcomesOrgan-at-risk (OAR) dose sparing, target coverage, homogeneity index, conformity index, dose-volume histogram parameters

Bottom Line

This dosimetric study demonstrates that simultaneous optimization of multiple photon energies (2-18 MV) can improve organ-at-risk sparing in prostate radiotherapy without compromising target coverage. Triple-energy IMRT showed the greatest benefit, reducing bladder and rectal mean doses by up to 1.6 Gy compared to standard single-energy approaches. While the Monte Carlo validation was robust and statistical significance was achieved, the study is limited by small sample size and lack of clinical deliverability assessment. The technique requires sophisticated planning systems and multi-energy capable linacs, which may limit immediate clinical implementation. Further research is needed to demonstrate practical deliverability and clinical outcomes before routine adoption.

Evidence: Moderate

Key Findings

  • P Value: p = 0.001 for bladder and rectal mean dose reductions

  • Effect Size: Mean dose reductions up to 1.6 Gy for bladder and rectum with triple-energy IMRT

  • Primary Outcome: Multi-energy optimization achieved superior OAR sparing compared to single-energy plans

  • Nnt Or Sensitivity: V10 reductions of approximately 8% for bladder and rectum

  • Confidence Interval: Not reported

Clinical Application

Requires advanced treatment planning systems capable of multi-energy optimization and linacs with multiple energy options Relevant to Australian radiation oncology centres with modern linacs; aligns with RANZCR guidelines for prostate cancer treatment optimization Prostate cancer patients receiving definitive radiotherapy with IMRT or VMAT

Abstract

Objective.This study aimed to develop and evaluate a framework for the simultaneous optimization of beam fluence and multiple photon energies beyond dual-energy configurations for intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT), with the goal of improving treatment plan quality and normal tissue sparing.Approach.An Elekta Versa HD linear accelerator (linac) was modeled using the BEAMnrc/EGSnrc Monte Carlo platform to simulate 2 MV, 4 MV, and 6 MV photon beams, complemented with measured beam data for 10 MV and 18 MV. A custom MATLAB-based framework was developed to perform simultaneous optimization of energy and fluence, allowing energy weighting of individual beamlets. A total of 12 various energy configurations including single (SE), dual (DE), triple (TE), and quadruple (QE)-energy combinations for IMRT and VMAT were generated for thirteen prostate cancer patients. Plans were evaluated using dose-volume histograms, homogeneity index, conformity index, and organ-at-risk (OAR) dose metrics.Main results.Gamma analysis confirmed the high degree of agreement between measured and simulated beam data, which validated our Monte Carlo linac model. Target coverage remained comparable across all energy configurations. Compared with 6 SE, multi-energy (ME) IMRT and VMAT achieved superior OAR sparing, with the greatest benefits for bladder and rectum in the 5-40 Gy range. TE-IMRT reduced bladder and rectal mean doses by up to 1.6 Gy, with V10 reductions of ∼8%; on average, mean doses were reduced by 0.9 Gy (p= 0.001) and 1.0 Gy (p= 0.001). For VMAT, the 6&18 DE-VMAT plan yielded the largest sparing, lowering bladder and rectal mean doses by ∼1.0 Gy. Relative to 10 SE, all ME plans achieved equal or lower OAR doses, with TE-IMRT and 6&18 DE-VMAT showing the most consistent benefit, reducing mean doses to the bladder, rectum, right femoral head, and left femoral head by up to 1.26, 0.77, 0.6, and 0.55 Gy, respectively.Significance.This study presents the first assessment of the feasibility and potential clinical value of simultaneous optimization of beam intensity and more than two photon energies for IMRT and VMAT plans, producing optimized ME fluence maps that require subsequent conversion into clinically deliverable treatment plans. The findings demonstrate that ME optimization can enhance OAR sparing without compromising target coverage, supporting its promise for future clinical application.

References

  1. 1.Rohani, A., Guo, B., & Zhang, R. (2026). Dosimetric evaluation of simultaneous multi-energy (2-18 MV) and intensity optimization for IMRT and VMAT. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/ae6343
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service