Research Appraisaldiagnostic

Deep Learning Model Using Transfer Learning for Detecting Left Ventricular Systolic Dysfunction: Retrospective Algorithm Development and Validation Study

JMIR medical informaticsLee, Sungjae, Son, Jung-Woo, Kim, Sung-Ai et al.24 Apr 2026DOI

Clinical Snapshot

60CEBM
Evidence: Moderatediagnostic

PICO Framework

P — PopulationPatients undergoing paired transthoracic echocardiography and electrocardiography within 2-week intervals at 2 Korean hospitals
I — InterventionRecalibrated 12-lead DeepECG LVSD model using patient-wise recalibration with historical LVEF measurements
C — ComparatorUncalibrated 12-lead DeepECG LVSD model and conventional supervised learning approaches
O — OutcomesArea under receiver operating curve (AUROC) for detecting left ventricular systolic dysfunction, with internal and external validation

Bottom Line

This study presents a novel recalibration approach for AI-enhanced ECG interpretation that improves detection of left ventricular systolic dysfunction by incorporating longitudinal patient data. While the AUROC results are promising (0.956 internal, 0.940 external validation), the clinical utility remains unclear due to missing sensitivity and specificity data. The recalibration method shows particular promise for patients with comorbidities where standard AI-ECG models typically underperform. However, significant methodological limitations include insufficient detail for reproducibility, unclear blinding procedures, and no assessment of clinical impact. The Korean hospital population may limit generalizability to Australian practice. Before clinical implementation, this technology would require comprehensive validation including sensitivity/specificity analysis, clinical utility studies, and regulatory approval. The approach represents an interesting advancement in AI-ECG technology but needs more robust validation for routine clinical use.

Evidence: Moderate

Key Findings

  • P Value: P<0.001 for recalibration improvement

  • Effect Size: Recalibrated model AUROC 0.956 (internal) vs 0.940 (external validation)

  • Primary Outcome: Area under receiver operating curve for LVSD detection

  • Nnt Or Sensitivity: Sensitivity and specificity not reported - major limitation for clinical application

  • Confidence Interval: Internal: 95% CI 0.946-0.965; External: 95% CI 0.936-0.945

Clinical Application

Requires integration with existing ECG and echocardiography systems; computational resources for deep learning model deployment Would require TGA approval as medical device; potential integration with existing cardiac monitoring programs; cost-effectiveness analysis needed for PBS consideration Patients requiring longitudinal monitoring for LVSD, particularly those with comorbidities where traditional AI-ECG models show degraded performance

Abstract

BACKGROUND: Artificial intelligence-augmented electrocardiogram (AI-ECG) models for detecting left ventricular systolic dysfunction (LVSD) often exhibit degraded performance in patients with comorbidities. OBJECTIVE: This study aimed to introduce and validate a recalibration method using longitudinal patient data to enhance prediction accuracy and simulate its clinical utility for ongoing monitoring. METHODS: We conducted a multicenter, retrospective cohort study using data from 2 hospitals in Korea. A dataset of paired transthoracic echocardiograms (TTEs) and electrocardiograms (ECGs) matched within a 2-week interval was constructed, separating pairs into baseline (first for each patient) and follow-up assessments. In addition to conventional supervised learning, we developed a patient-wise recalibration strategy that incorporated historical left ventricular ejection fraction measurements and prior AI-ECG outputs to adjust for future predictions, thus empirically mitigating confounding effects. Pretraining was also implemented to enhance the model's performance. RESULTS: The recalibrated 12-lead DeepECG LVSD model achieved an area under the receiver operating curve of 0.956 (95% CI 0.946-0.965) for internal validation and 0.940 (95% CI 0.936-0.945) for external validation of follow-up TTE-ECG pairs. The uncalibrated 12-lead DeepECG LVSD model also showed modest performance, with an area under the receiver operating curve of 0.953 (95% CI 0.941-0.965) in the internal validation and 0.947 (95% CI 0.943-0.951) in the external validation when tested on baseline TTE-ECG pairs. Recalibration yielded statistically significant improvements in the 12-lead DeepECG LVSD models (P<.001), with enhanced and more balanced performance across all clinical subgroups. CONCLUSIONS: Patient-wise recalibration improved accuracy and consistency across various comorbidities by mitigating performance degradation and bias. This broadens the application of AI-ECG for LVSD detection from low-risk screening to high-risk longitudinal monitoring.

References

  1. 1.Lee, S., Son, J. W., Kim, S. A., Ahn, M. S., Lee, S. J., Han, S. J., Joo, T., Na, Y., Joo, S., Ahn, H. J., Chang, M., Lee, Y., & Park, Y. J. (2026). Deep Learning Model Using Transfer Learning for Detecting Left Ventricular Systolic Dysfunction: Retrospective Algorithm Development and Validation Study. JMIR Medical Informatics, 14(1), e83127. https://doi.org/10.2196/83127
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service