Concordance between target trial emulation and randomised controlled trials: systematic review and meta-analysis
Clinical Snapshot
PICO Framework
| P — Population | Observational studies that explicitly aimed to emulate target randomised controlled trials of health interventions |
| I — Intervention | Target trial emulation methodology |
| C — Comparator | Corresponding randomised controlled trials (benchmark studies) |
| O — Outcomes | Concordance measured by Pearson correlation coefficients, standardised difference agreement, and ratio of ratios |
Bottom Line
This comprehensive meta-analysis of 107 target trial emulation studies demonstrates moderate concordance with corresponding RCTs (correlation 0.59), improving substantially to 0.83 with better emulation design. Key findings show systematic underestimation of effects for cardiovascular and thrombotic outcomes, overestimation for respiratory outcomes, and reduced concordance with claims-based data. The study provides crucial guidance for Australian researchers using administrative datasets, highlighting the importance of baseline balance, outcome definition quality, and multi-source data linkage. While target trial emulation shows promise as a complement to RCTs, careful attention to methodology is essential for reliable results.
Key Findings
P Value: Not explicitly reported
Effect Size: Pearson correlation coefficient 0.59 (overall), 0.83 (high-quality emulations)
Primary Outcome: Concordance between target trial emulations and RCTs
Nnt Or Sensitivity: 79% standardised difference agreement overall, 87% for high-quality emulations
Confidence Interval: 95% CI 0.45 to 0.70 (overall), 0.73 to 0.89 (high-quality)
Clinical Application
Highly feasible - provides methodological framework for improving emulation design Directly applicable to Australian researchers using administrative data (PBS, MBS) for comparative effectiveness research and TGA regulatory science Researchers conducting target trial emulations across diverse clinical domains
Abstract
OBJECTIVES: To assess the concordance of results between paired target trial emulations and their benchmarking randomised controlled trials and to explore determinants of emulation success. DESIGN: Systematic review and meta-analysis. DATA SOURCES: Medline, EMBASE, Scopus, PsycINFO, and Web of Science (2010 to 2025). STUDY SELECTION: Observational studies that explicitly aimed to emulate target randomised controlled trials of a health intervention were included. DATA EXTRACTION: Data were extracted on study domain, target population, intervention, comparator, and main outcomes for each emulation and corresponding randomised controlled trial. MAIN OUTCOME MEASURES: For 21 predefined emulation design features, concordance was assessed using Pearson correlation coefficients, standardised difference agreement, and ratio of ratios, with subgroup and regression analyses of study characteristics and concordance. RESULTS: Among 107 target trial emulation-randomised controlled trial pairs, the Pearson correlation coefficient was 0.59 (95% confidence interval (CI) 0.45 to 0.70), standardised difference agreement was 79% (85/107), and summary ratio of ratios was 0.96 (95% CI 0.92 to 1.01; I2=36%). In 63 pairs with closer emulation of trial design, a higher level of agreement was observed, with a Pearson correlation coefficient of 0.83 (0.73 to 0.89) and standardised difference agreement of 87% (55/63). In subgroup analysis, trial emulations tended to systematically underestimate treatment effects from randomised controlled trials for specific outcomes related to venous thromboembolism and major adverse cardiovascular events, while overestimating those for respiratory outcomes, with pooled ratio of ratios of 0.76 (0.58 to 1.00; I2=40%), 0.91 (0.86 to 0.96; I2=32%), and 1.20 (1.03 to 1.40; I2=40%), respectively. Moreover, emulations based on claims data tended to underestimate the treatment effects (ratio of ratios 0.90, 0.82 to 0.99; I2=38%). In univariate regression analyses, poorer target trial emulation-randomised controlled trial concordance was associated with emulation designs with imbalanced baseline population characteristics, treatment started in hospital, and lower outcome emulation quality. CONCLUSIONS: Current target trial emulations achieve moderate concordance when replicating their corresponding randomised controlled trials. Concordance could be improved by better emulation design, including better baseline and outcome emulation and leveraging multisource linked databases. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42024619811.
References
- 1.Wang, C., Tang, D., von Dadelszen, P., Ju, C., Liu, L., Wang, Y., & Magee, L. A. (2026). Concordance between target trial emulation and randomised controlled trials: systematic review and meta-analysis. BMJ, bmj-2025-086810. https://doi.org/10.1136/bmj-2025-086810
Related Research
Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy
Ventral hernia repair in emergency settings. A machine learning model to predict post-operative complications.
3 Aug 2026
Journal of the American Medical Informatics Association : JAMIA
Sociodemographic bias in large language model clinical trial screening
2 Aug 2026
Acta odontologica Scandinavica
Predicting gingival embrasure risk after invisible orthodontics using multimodal data and machine learning
23 July 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service