Automatic segmentation of clinical target volume for radiation therapy in breast-conserving patients and exploration of clinical factors influential to its performance
Clinical Snapshot
PICO Framework
| P — Population | 857 breast cancer patients undergoing breast-conserving surgery from a single center in China |
| I — Intervention | Deep learning model for automatic clinical target volume (CTV) contouring |
| C — Comparator | Manual contouring by radiation oncologists |
| O — Outcomes | Dice Similarity Coefficient (DSC), 95th percentile Hausdorff Distance (HD95), contouring time, dosimetric parameters, clinical acceptability ratings |
Bottom Line
This validation study demonstrates that deep learning models can achieve clinically acceptable accuracy for breast clinical target volume contouring, with geometric performance comparable to expert physicians and significant time savings. The median Dice coefficients exceeded 0.93 with Hausdorff distances under 2.5mm. However, performance degrades with peripheral tumor beds and low-density breast tissue. While promising for workflow efficiency, the single-center Chinese dataset limits generalizability to Australian practice. Clinical implementation would require local validation, particularly given variations in contouring practices and patient demographics. The technology shows potential for reducing radiation oncologist workload while maintaining dosimetric quality, but careful quality assurance protocols would be essential before clinical adoption.
Key Findings
P Value: P = 0.005 for time savings; P < 0.001 for clinical factors
Effect Size: Median DSC: 0.941 (left), 0.937 (right); HD95: 1.75mm (left), 2.47mm (right)
Primary Outcome: Geometric accuracy measured by Dice Similarity Coefficient and Hausdorff Distance
Nnt Or Sensitivity: Auto-contouring outperformed 1/5 physicians by DSC and 3/5 by HD95
Confidence Interval: Not consistently reported
Clinical Application
Requires deep learning infrastructure and validation in local practice settings Relevant to Australian radiation oncology practice but requires validation in local population and integration with existing TGA-approved planning systems Breast cancer patients undergoing breast-conserving surgery requiring radiation therapy planning
Abstract
OBJECTIVES: To develop and validate a deep learning model for whole breast clinical target volume (CTV) contouring and evaluate clinical features affecting its performance. METHODS: Five datasets with 857 patients from a single center were used. Dataset 1 (n = 300) trained and tested the model. Dataset 2 (n = 10) evaluated contouring time and dosimetric parameters. Datasets 3 (n = 20) and 4 (n = 10) were for clinical evaluation. Dataset 5 (n = 517) identified clinical factors influencing auto-contouring accuracy. Model performance was assessed using Dice Similarity Coefficient (DSC) and 95th percentile Hausdorff Distance (HD95). RESULTS: The median DSC and HD95 for left- and right-sided models in Dataset 1 were 0.941, 1.75 mm and 0.937, 2.47 mm, respectively. In Dataset 2, both auto-contouring and auto-contouring with manual corrections were significantly faster than manual contouring (P = .005 for both), while still achieving clinically acceptable dosimetric results. In Dataset 3, two physicians rated automatic and manual contours as equivalent (P = .214, P = .075), while the other rated auto-contouring higher (P < .001). In Dataset 4, the auto-contouring model outperformed 1/5 physicians by DSC (P = .009) and 3/5 by HD95 (P = .015, P = .007, P = .017). In Dataset 5, peripheral tumor-bed and low-density breast tissue were associated with lower DSC (P < .001 for both) and higher HD95 (P < .001 for both). Cases without unfavorable factors performed better than those with (P < .001 for both). CONCLUSIONS: The proposed model demonstrated acceptable accuracy, consistency, and efficiency in breast CTV contouring. Peripheral tumor-bed and low-density breast tissue reduced auto-contouring performance. ADVANCES IN KNOWLEDGE: The characteristics of challenging cases in whole breast CTV auto-contouring should be identified.
References
- 1.Zhang, M., Zhang, Y., Cao, L., Cai, R., Xu, H., Xu, C., Xiong, W., Zhang, W., Wu, X., Chen, J., & Cai, G. (2024). Automatic segmentation of clinical target volume for radiation therapy in breast-conserving patients and exploration of clinical factors influential to its performance. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag036
Related Research
Medical physics
Reference-Free large language model agents for physician-guided radiotherapy treatment planning
2 Aug 2026
Cancer medicine
Applications of Artificial Intelligence in Cancer Diagnosis and Treatment
1 Aug 2026
Acta oncologica (Stockholm, Sweden)
User perceptions of machine learning models as decision support for colorectal cancer multidisciplinary team conferences (AID-SIM-2): a qualitative simulation study.
1 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service