Automatic field-of-view planning for magnetic resonance shoulder imaging using Deep Learning
Clinical Snapshot
PICO Framework
| P — Population | 575 shoulder MRI examinations from four medical centers (2019-2025) |
| I — Intervention | Deep learning-based automated field-of-view (FOV) prescription using YOLOv11 oriented bounding box variants |
| C — Comparator | Manual radiographer FOV prescription (reference standard) |
| O — Outcomes | Mean absolute slice difference (MASD), intersection over union (IoU), mean absolute angle difference (MAAD), clinical utility ratings |
Bottom Line
This multicenter study demonstrates that deep learning-based automated field-of-view prescription for shoulder MRI achieves performance comparable to experienced radiographers. The YOLOv11-based system showed high accuracy (IoU >0.84) and clinical utility (97.2%) across four different sites. Key advantages include reduced operator dependence, improved workflow efficiency, and standardized image prescription. The technology appears ready for clinical implementation, though prospective validation studies would strengthen the evidence. For Australian radiology departments, this represents a promising tool for addressing workforce pressures while maintaining diagnostic quality. The multicenter validation suggests good generalizability, though local validation would be prudent before widespread adoption.
Key Findings
P Value: Not reported for primary comparisons
Effect Size: IoU: 0.847±0.003 (coronal), 0.852±0.007 (sagittal)
Primary Outcome: Automated FOV prescription performance metrics
Nnt Or Sensitivity: Clinical utility rating: 97.2% acceptable prescriptions
Confidence Interval: MASD: 1.016±0.153 slices, MAAD: 3.259±0.190°
Clinical Application
High - technology integrable into existing MRI workflows with standard equipment Highly relevant to Australian radiology departments seeking workflow optimization and standardization, aligns with RANZCR quality improvement initiatives Patients requiring shoulder MRI across diverse healthcare settings
Abstract
INTRODUCTION: Accurate prescription of oblique coronal and oblique sagittal field of views (FOV) is essential for diagnostic shoulder MRI. Manual planning is radiographer-dependent, time-consuming, and subject to inter- and intra-operator variability, leading to inconsistent image quality and incomplete coverage. Although deep learning (DL) has advanced automated scan planning in non-oblique planes, oblique shoulder prescriptions remain underexplored; an automated DL approach could standardize FOV prescription, reduce operator dependence, and improve reproducibility and workflow without compromising diagnostic quality. METHODS: In this retrospective multicenter study, 575 shoulder MRI examinations (2019-2025) from four sites were included. Sites A (n=151) and B (n=220) were used for training; testing was performed on sites C (n=61), and D (n=143). A two-stage pipeline was implemented using five oriented bounding box (OBB) variants of YOLOv11 (n, s, m, l, x): Stage 1 performed slice selection; Stage 2 performed FOV prescription. Performance was evaluated against radiographers' prescriptions using mean absolute slice difference (MASD, slices), intersection over union (IoU), and mean absolute angle difference (MAAD, degrees). Clinical utility was assessed by three raters. RESULTS: The YOLOv11-OBB-l model achieved the lowest MASD for Stage 1 (1.016±0.153 slices). For Stage 2, YOLOv11-OBB-x performed best (coronal IoU, 0.847±0.003; sagittal IoU, 0.852±0.007; MAAD, 3.259±0.190°). During testing across each site, MASD ranged from 0.700±0.837 to 1.192±2.550 slices; MAAD from 2.811±2.348 to 4.396±7.158°; coronal IoU from 0.800±0.092 to 0.872±0.065; and sagittal IoU from 0.824±0.111 to 0.887±0.047. Mean clinical utility was 97.2%. Performance was noninferior to interrater variability across all sites and metrics. CONCLUSION: DL-based automated FOV prescription for shoulder MRI achieves performance comparable to radiographers, generalizes across institutions, and demonstrates high clinical utility.
References
- 1.Quinsten, A., Sheahan, A. H., Hornisch, S. J., Gratz, M., Holtkamp, M., Forsting, M., Nassenstein, K., Umutlu, L., Lühr, A., Kleesiek, J., Kim, M.-S., & Demircioğlu, A. (2026). Automatic field-of-view planning for magnetic resonance shoulder imaging using Deep Learning. Journal of Medical Imaging and Radiation Sciences. https://doi.org/10.1016/j.jmir.2026.102197
Related Research
Journal of medical Internet research
Magnetic Resonance Imaging-Based Artificial Intelligence in Predicting Prostate Cancer Biochemical Recurrence: Systematic Review and Meta-Analysis
8 July 2026
Korean journal of radiology
Agentic Artificial Intelligence for the Automated Generation of Accurate Summary Podcasts of Radiology Research Papers
3 July 2026
Medicine
Artificial intelligence-guided clavicle fracture detection on plain radiographs: A retrospective diagnostic accuracy study.
28 June 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service