Assessing the relevance of biosignal-controlled robotic rehabilitation technologies: a systematic review.
Clinical Snapshot
PICO Framework
| P — Population | Adults undergoing rehabilitation for physical or neurological impairments (including stroke, spinal cord injury, and other conditions causing motor dysfunction), with no restriction to a single disease-specific population |
| I — Intervention | Robot-assisted rehabilitation systems controlled by biosignals — primarily electromyography (EMG), electroencephalography (EEG), or electrocardiography (ECG) — providing closed-loop, real-time feedback-driven therapy |
| C — Comparator | Conventional rehabilitation care (physiotherapy, occupational therapy, or standard robotic rehabilitation without biosignal control); comparators varied across included studies |
| O — Outcomes | Measurable rehabilitative outcomes including improvements in motor function, muscle activity reduction, mobility, and other clinical metrics; secondary outcomes implied but not uniformly pre-specified |
Bottom Line
This PRISMA-guided systematic review synthesises recent evidence (2020–2025) on biosignal-controlled robotic rehabilitation, identifying only 15 eligible studies from 207 screened records. The review's central finding — that EMG-driven robotic systems may support more personalised and intensive rehabilitation than conventional care — is directionally plausible but remains quantitatively unsubstantiated. No meta-analysis was performed, no GRADE assessment was conducted, and the included studies are acknowledged to be heterogeneous and underpowered. Critical clinical outcomes including adverse events, adherence, cost-effectiveness, and user experience are largely absent from the evidence base. For senior clinicians, the honest appraisal is that this review maps the current landscape of an emerging technology rather than providing actionable efficacy data. Biosignal-controlled robotic rehabilitation is not yet supported by evidence sufficient to change practice or justify broad clinical adoption. The authors' own recommendations — adequately powered head-to-head trials, standardised outcome measures, longer follow-up, and transparent safety reporting — represent the minimum evidentiary threshold before these systems should be considered for routine use. In the Australian context, NDIS and TGA pathways exist for device deployment, but clinical guideline endorsement awaits a substantially stronger evidence base.
Key Findings
P Value: Not reported at the review level; individual study-level statistics not summarised in the abstract
Effect Size: Not quantified; no pooled effect size reported. Narrative synthesis suggests directionally positive effects for EMG-driven systems on motor performance outcomes
Primary Outcome: Improvements in motor function and reduction in muscle activity (EMG-measured) in patients undergoing biosignal-controlled robotic rehabilitation, assessed narratively across 15 included studies
Nnt Or Sensitivity: Not calculable from available data; no NNT, sensitivity/specificity, or hazard ratio reported. The absence of quantitative synthesis is a critical limitation for clinical decision-making
Confidence Interval: Not reported; no meta-analytic synthesis performed
Clinical Application
Biosignal-controlled robotic rehabilitation systems (particularly EMG-driven exoskeletons and end-effector devices) are technically feasible in well-resourced rehabilitation centres. However, barriers to widespread clinical adoption remain substantial: high equipment costs, requirement for specialist technical training, lack of standardised protocols, and absence of robust safety and usability data. The technology readiness level for routine clinical use appears low based on the current evidence base. In Australia, robotic rehabilitation technologies are not currently listed on the Pharmaceutical Benefits Scheme (PBS), as they are devices rather than pharmaceuticals. Funding pathways may exist through the National Disability Insurance Scheme (NDIS) for eligible participants, or through private health insurance extras cover, though coverage is inconsistent. The Therapeutic Goods Administration (TGA) regulates medical devices including robotic rehabilitation systems under the Australian Register of Therapeutic Goods (ARTG); any commercially deployed system would require appropriate classification and registration. The RACGP and the Australasian Faculty of Rehabilitation Medicine (AFRM) have not issued specific guidelines on biosignal-controlled robotic rehabilitation, reflecting the early-stage evidence base. Australian rehabilitation services, particularly in rural and remote settings, face additional access barriers that make the scalability of these technologies uncertain. The growing burden of stroke and neurological disability in an ageing Australian population (consistent with the global trends cited by the authors) provides a compelling rationale for continued investment in this research area, but current evidence does not support routine clinical adoption. Adults with physical or neurological impairments requiring motor rehabilitation — including but not limited to stroke survivors, spinal cord injury patients, and those with neurodegenerative conditions affecting motor function. The disease-agnostic framing means no single patient group can be identified as the primary beneficiary from current evidence.
Abstract
Technology is transforming rehabilitative medicine by enhancing accessibility and personalisation. Robot-assisted rehabilitation uses robotic systems for recovery from physical and neurological impairments, enabling intensive, repetitive training with real-time feedback. These systems aim to restore motor function and mobility and to increase independence in daily life, needs that are growing in light of population ageing. Rather than revisiting control algorithms or mechanical design, this review aims to investigate the combined use of bio-signals and robotic rehabilitation systems, and to discuss their potential in rehabilitation settings outside disease-specific clinical frameworks. We reviewed studies published from 2020 through early 2025 to capture recent advances in this rapidly evolving field. Our objective was to assess the relevance of these technologies to rehabilitation outcomes, such as improvements in motor function or other clinical metrics. We considered robot-assisted systems driven by biosignals such as electromyography (EMG), electroencephalography, or electrocardiography and included only studies reporting measurable rehabilitative outcomes. Following PRISMA guidelines, we searched Scopus, PubMed, and WoS databases. Of 207 records screened, 15 met the inclusion criteria. Overall, the included studies suggest that contemporary biosignal-controlled robotic rehabilitation, particularly EMG-driven approaches, may support more intensive, personalised, and engaging therapy than conventional care alone, although the current evidence remains preliminary. Preliminary findings indicate that, by closing the loop among patient, device, and therapist, these systems may reduce muscle activity and support improvements in motor performance; however, the evidence base remains heterogeneous and generally underpowered. To support future clinical adoption, the field needs adequately sized, head-to-head trials with standardised outcome measures, longer follow-up, and transparent reporting of adherence, adverse events, user experience, and implementation barriers, including training and cost. These steps will be important to further assess efficacy and evaluate usability in real-world settings.
References
- 1.Santoriello, V., Cesarelli, G., Ficuciello, F., Giugliano, C., Angelone, F., Russo, M., Ponsiglione, A. M., & Romano, M. (2026). Assessing the relevance of biosignal-controlled robotic rehabilitation technologies: a systematic review. Progress in Biomedical Engineering. https://doi.org/10.1088/2516-1091/ae7862
Related Research
IEEE transactions on cybernetics
Knowledge Distillation and Reinforcement Learning in a Human–Machine Collaboration Delivery System With a Robotic Arm
3 Aug 2026
The Journal of rheumatology
Examining the Role of Wearables in Inflammatory Arthritis Care: A Narrative Literature Review
3 Aug 2026
Science advances
Human-inspired time-series health evaluation with an adaptive multimodal electronic skin
3 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service