An exploratory dosimetric and treatment-time analysis of tangent-arc and continuous semi-arc VMAT in deep inspiration breath-hold radiotherapy for stage I left-sided breast cancer
Clinical Snapshot
PICO Framework
| P — Population | Twenty patients with stage I left-sided breast cancer treated with deep inspiration breath-hold (DIBH) radiotherapy |
| I — Intervention | Tangent-arc VMAT radiotherapy planning |
| C — Comparator | Continuous semi-arc VMAT radiotherapy planning |
| O — Outcomes | Dosimetric parameters (conformity index, organ at risk doses), beam-on time, total treatment time, and treatment time trends across fractions |
Bottom Line
This exploratory dosimetric study compared two VMAT techniques for left breast cancer radiotherapy using deep inspiration breath-hold in 20 patients. Tangent-arc plans demonstrated lower radiation doses to organs at risk and shorter beam-on times compared to continuous semi-arc plans, while maintaining adequate target coverage. Treatment times stabilized across fractions, suggesting patient adaptation to the DIBH technique. However, the study's limitations include a very small sample size, single-center design, and lack of clinical outcome data. While the dosimetric advantages of tangent-arc VMAT are encouraging, these preliminary findings require validation in larger, multicenter studies before informing routine clinical practice. Australian radiation oncologists should interpret these results cautiously and consider local validation studies.
Key Findings
P Value: P < 0.05 for most organ at risk comparisons and beam-on time
Effect Size: Tangent-arc plans showed significantly lower organ at risk doses and beam-on times while maintaining adequate PTV coverage
Primary Outcome: Dosimetric comparison between tangent-arc and continuous semi-arc VMAT techniques
Nnt Or Sensitivity: Conformity index significantly better with continuous semi-arc (specific values not provided in abstract)
Confidence Interval: Not reported
Clinical Application
Requires VMAT-capable linear accelerators and DIBH monitoring systems, standard in most Australian radiation oncology centers Relevant to Australian practice where DIBH is increasingly used for left breast cancer. Results may inform technique selection but require local validation given single-center origin Patients with stage I left-sided breast cancer suitable for DIBH radiotherapy
Abstract
BACKGROUND: The use of the deep inspiration breath-hold (DIBH) technique reduces cardiac and lung radiation exposure during left breast cancer radiotherapy. However, the optimal beam delivery technique and the effects of patient adaptation during DIBH remain incompletely understood. OBJECTIVE: In this study, the dosimetric differences between continuous semi-arc and tangent-arc plans in stage I left-sided breast cancer patients using DIBH were compared, and the treatment session duration was descriptively analyzed to characterize treatment-time trends during routine DIBH delivery. METHODS: Twenty patients treated at our hospital from 01/05/2022-31/05/2023 were retrospectively selected from the institutional database for exploratory dosimetric analysis. Two radiotherapy plans were created on the basis of each patient's computed tomography (CT) images. Dosimetric parameters for the planning target volume (PTV) and organs at risk (OARs), and beam-on and total treatment times, were compared. RESULTS: The conformity index (CI) for the PTV was significantly better with the continuous semi-arc plan (P < 0.05), whereas the other PTV parameters did not significantly differ between the plans (P > 0.05). The doses and beam-on time for all OARs (except the left ventricle) were significantly lower for the tangent-arc plan (P < 0.05). Treatment time tended to stabilize across fractions, with a significant difference between the 15th and 16th sessions (P < 0.05). CONCLUSION: With the tangent-arc plan, the beam-on time and radiation exposure to OARs were observed to be lower, while adequate PTV coverage was maintained in patients with stage I left-sided breast cancer using DIBH. Treatment times tended to stabilize with increasing treatment fractions. This observation suggests gradual patient adaptation during routine DIBH rather than a predefined training effect. Given the exploratory nature of these findings and the limited sample size from a single institution, these findings should be interpreted with caution and warrant further investigation in larger, multicenter studies.
References
- 1.Li, Y., Chen, Y., Xu, C., Zhan, W., Shao, K., Jia, Y., Zhang, H., Qiu, L., Ding, J., & Chen, W. (2026). An exploratory dosimetric and treatment-time analysis of tangent-arc and continuous semi-arc VMAT in deep inspiration breath-hold radiotherapy for stage I left-sided breast cancer. PLoS One. https://doi.org/10.1371/journal.pone.0348570
Related Research
Medical physics
Reference-Free large language model agents for physician-guided radiotherapy treatment planning
2 Aug 2026
Cancer medicine
Applications of Artificial Intelligence in Cancer Diagnosis and Treatment
1 Aug 2026
Acta oncologica (Stockholm, Sweden)
User perceptions of machine learning models as decision support for colorectal cancer multidisciplinary team conferences (AID-SIM-2): a qualitative simulation study.
1 Aug 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service