Research Appraisalobservational

Alignment Between Cardiologists and AI-Driven Diagnostic Systems: Mixed Methods Study

Journal of medical Internet researchMahdavi, Mahdi, White, Sarah, Hothi, Sandeep S et al.20 May 2026DOI

Clinical Snapshot

100CEBM
Evidence: Moderateobservational

PICO Framework

P — Population854 participants with suspected coronary artery disease from the PROTEUS trial, plus 61 UK consultant cardiologists
I — InterventionAI-driven stress echocardiography system (EchoGo Pro)
C — ComparatorCardiologist clinical diagnosis
O — OutcomesDiagnostic concordance, predictors of agreement/disagreement, scan rejection rates, cardiologist decision-making strategies

Bottom Line

This mixed-methods study of 854 patients found 60% concordance between an AI stress echocardiography system and cardiologist diagnoses for coronary artery disease. Agreement was significantly lower in patients with hypertension, diabetes, and prior CAD—precisely the populations where diagnostic accuracy matters most. The AI system rejected over a quarter of scans due to image quality issues, with higher rejection rates in men and those with family CAD history. Surveyed cardiologists viewed AI as advisory rather than definitive, requiring 65-69% confidence in their diagnosis to override AI recommendations. Paradoxically, those with higher AI confidence needed greater diagnostic certainty to disagree with the system. While AI may identify additional at-risk patients when used alongside clinical judgment, the high rejection rates and reduced performance in complex patients limit immediate clinical utility. The technology shows promise as a decision support tool but requires significant refinement before widespread implementation, particularly better integration of clinical context and reduced bias in training datasets.

Evidence: Moderate

Key Findings

  • P Value: P=.01 for hypertension, P=.02 for diabetes, P=.002 for prior CAD

  • Effect Size: Reduced concordance in hypertension (OR 0.58), diabetes (OR 0.56), and prior CAD (OR 0.48)

  • Primary Outcome: 60% diagnostic concordance between AI system and cardiologists

  • Nnt Or Sensitivity: AI rejection rate 26.1%, with combined AI-clinician approach identifying additional 4.2% positive cases

  • Confidence Interval: 95% CI 0.38-0.89 for hypertension association

Clinical Application

Moderate feasibility given high rejection rates and need for quality imaging. Requires integration with clinical workflow and decision support systems Relevant to Australian cardiology practice. Consider TGA approval pathways for AI diagnostic tools. May complement Medicare-funded stress echocardiography (item 55118). Aligns with CSANZ guidelines for CAD assessment Patients with suspected coronary artery disease undergoing stress echocardiography, particularly those without complex comorbidities

Abstract

BACKGROUND: The clinical value of artificial intelligence (AI)-based diagnostic systems depends not only on their accuracy but also on how well their outputs integrate with clinicians' judgments in practice. Critical knowledge gaps remain regarding diagnostic concordance between AI and clinicians in stress echocardiography interpretation, patient characteristics predicting discordance, and how cardiologists respond when AI recommendations conflict with their clinical diagnoses. OBJECTIVE: This study examined the diagnostic alignment between an AI-driven stress echocardiography system (EchoGo Pro [EGP]) and cardiologists' diagnoses of coronary artery disease (CAD), identified predictors of concordance and AI scan rejection, and explored cardiologists' decision-making strategies when disagreements arise. METHODS: We conducted mixed methods research. The quantitative study analyzed concordance between EGP and cardiologists using data from 854 participants with suspected CAD in the multicenter PROTEUS randomized controlled trial. Logistic regression identified predictors of agreement, disagreement, and scan rejection, adjusting for age, sex, smoking status, BMI, and cardiovascular risk factors (hypertension, hypercholesterolemia, diabetes, family history of CAD, and prior CAD events). To gain deeper insight into discordance, we conducted a qualitative study analyzing survey responses from 61 UK consultant cardiologists recruited via Qualtrics, exploring their perceptions of AI tools, the risks of following discordant AI recommendations, and their typical responses to AI-clinician disagreement. RESULTS: EGP and cardiologists agreed in 60% (512/854) of the cases, but agreement was significantly lower among patients with hypertension (OR 0.58, 95% CI 0.38-0.89; P=.01), diabetes (OR 0.56, 95% CI 0.35-0.90; P=.02), and pre-existing CAD (OR 0.48, 95% CI 0.30-0.77; P=.002). EGP rejected 26.1% (222/854) of the scans due to insufficient image quality, with rejection significantly more common in male patients (β=0.35; P=.03) and those with a family history of CAD. If a positive CAD diagnosis was assigned when either cardiologists or EGP identified CAD, the proportion of positive cases increased from 17.9% (153/854) to 22.1% (189/854), potentially identifying additional at-risk patients. Survey respondents (50/60, 85% male; 26/57, 46% aged 40-49 years; 39/61, 64% White) required 65% to 69% confidence in their initial diagnosis to justify disregarding contradictory AI recommendations. The survey findings revealed cardiologists treated AI recommendations as advisory rather than definitive. When facing discordance, they retained confidence in their judgment and sought corroboration through additional testing, data review, or second opinions rather than deferring to AI. Paradoxically, cardiologists with higher confidence in AI tools required greater confidence in their own diagnosis to disregard AI recommendations (β=7.73; P=.02). Cardiologists attributed discordance primarily to AI's inability to incorporate patient history, comorbidities, and broader clinical context. CONCLUSIONS: EGP shows promise as an adjunctive tool but struggles with multimorbid patients and exhibits high, uneven rejection rates. Cardiologists use AI to prompt scrutiny, not replace judgment. Future systems need to integrate wider patient data with imaging and minimize bias through representative training to avoid exacerbating inequities.

References

  1. 1.Mahdavi, M., White, S., Hothi, S. S., Flood, C., Panayotova, R., & Frings, D. (2026). Alignment between cardiologists and AI-driven diagnostic systems: Mixed methods study. Journal of Medical Internet Research, 28(5), e83541. https://doi.org/10.2196/83541
Share:XLinkedIn

This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service