Bottom Line
This small pilot RCT found no significant differences in peri-implant tissue health between PEEK and cobalt-chromium telescopic crowns for mandibular overdentures over 12 months. While PEEK demonstrated comparable performance to the established CoCr standard, the study's major limitations include very small sample size (6 patients per group), unclear randomization methodology, and lack of confidence intervals. The minimal differences observed (0.03mm in bone loss) are not clinically meaningful. PEEK may offer a viable metal-free alternative for patients with aesthetic concerns or metal sensitivities, but these preliminary findings require confirmation in adequately powered, longer-term studies before changing clinical practice. Clinicians should consider patient-specific factors and cost implications when selecting crown materials for telescopic overdenture systems.
Key Findings
P Value: p = 0.735 for MBL; p = 0.411 for PD; p > 0.05 for PI
Effect Size: Mean difference of 0.03mm (CoCr: 0.48±0.15mm vs PEEK: 0.45±0.16mm)
Primary Outcome: Marginal bone loss at 12 months
Nnt Or Sensitivity: Not applicable - no significant treatment effect demonstrated
Confidence Interval: Not reported
Clinical Application
PEEK crowns require CAD/CAM milling capabilities but are technically feasible in modern dental practices Both materials available through Australian dental laboratories; PEEK may offer aesthetic advantages for patients with metal allergies, though cost-effectiveness requires evaluation within PBS framework Completely edentulous patients requiring implant-retained mandibular overdentures with telescopic crown retention
Abstract
PURPOSE: This pilot randomized clinical trial compared peri-implant tissue health around milled cobalt-chromium (CoCr) versus polyether ether ketone (PEEK) secondary telescopic crowns in implant-retained mandibular overdentures over 12 months. METHODS: Twelve completely edentulous patients received two implants each. After randomization, secondary crowns were fabricated from milled CoCr (n = 6 patients) or PEEK (n = 6 patients). Assessor-blinded outcome assessments such as marginal bone loss (MBL), probing depth (PD), and plaque index (PI) were performed at baseline, 6, 9, and 12 months post-loading. Statistical analysis used the patient as the unit of analysis. RESULTS: No statistically significant inter-group differences were found at any time point. At 12 months, mean MBL was 0.48 ± 0.15 mm for CoCr and 0.45 ± 0.16 mm for PEEK (p = 0.735). PD increased over time within groups but remained comparable between groups (CoCr: 2.58 ± 0.58 mm, PEEK: 2.33 ± 0.41 mm at 12 months; p = 0.411). PI scores also showed no significant inter-group differences (p > 0.05). CONCLUSIONS: Over 12 months, milled PEEK and CoCr secondary telescopic crowns demonstrated comparable peri-implant tissue health. PEEK presents a viable metal-free alternative for this application. These preliminary findings warrant confirmation in larger, long-term studies.
References
- 1.El Asfahani, I. A., Khalifa, A., Tawfik, D., Agamy, E., & Salloum, M. G. (2026). A randomized controlled pilot trial comparing peri-implant tissue health beneath CAD/CAM-milled PEEK versus cobalt-chromium telescopic crowns for mandibular overdentures. International Journal of Implant Dentistry. https://doi.org/10.21608/mjmr.2021.231551
Related Research
International dental journal
Deep Learning Based on Swin-Transformer and 3D U-Net: Implant Three-Dimensional Position Planning
2 Aug 2026
Journal of prosthodontic research
Peri-implant soft-tissue responses to tooth-colored abutment materials: A systematic review.
14 July 2026
BMC oral health
Accuracy of virtual facebow compared to conventional facebow: a systematic review
13 July 2026
This content is for educational purposes for healthcare professionals only and does not constitute clinical advice. Clinical decisions should be based on individual patient assessment, current guidelines, and appropriate specialist consultation. Editorial Standards · Privacy Policy · Terms of Service